CoChat

A simple, rapid immunometric assay for determination of functional and growth hormone‐occupied growth hormone‐binding protein in human serum

FISKER, S., FRYSTYK, J., SKRIVER, L., VESTBO, E., HO, K. K. Y., ØRSKOV, H. · 1996 · European Journal of Clinical Investigation
Cited by 69

The DOI matches its Crossref record.

Abstract

We present a sensitive time‐resolved fluorometric immunofunctional assay (TR‐FIA) for direct quantitation of functional growth hormone‐binding protein (GHBP), using an immunoassay kit for growth hormone (GH‐DELFIA). In addition to the immobilized GH antibody, one monoclonal antibody against GHBP was used. This anti‐GHBP was labelled with the chelate of europium. The assay was performed in one step. The detection limit for GHBP was 0.044 nmol L–1 (NBS + 3 SD). The calibration curve was linear in the interval 0.11–8.03 nmol L−1. Average intra‐assay coefficient of variation (CV) was 3.44%. Average interassay CV at GHBP concentrations 0.563 nmol L−1 and 1.40 nmol L−1 were 12% and 6.3% respectively. Analytical recovery in serum ranged from 76% to 127% with a mean of 101 ± 3.6%. Serum GHBP in 102 normal subjects ranged from 0.513 to 3.772 nmol L 1 and was positively related to body mass index (P < 0.001). In growth hormone‐deficient sera GHBP was higher than in control subjects (1.751 ± 0.179 nmol L−1 and 1.257 ± 0.140 nmol L−1 respectively, P < 0.001). Acromegalic patients had lower levels of GHBP than controls (0.946 ± 0.251 and 1.234 ± 0.144 nmol L−1 respectively, P = 0.005). This assay also allowed detection of GH‐complexed GHBP in serum. These results were in agreement with theoretical values calculated from the measured GH and the functional GHBP concentrations. Results were compared with data obtained by a recently reported, validated ligand immunofunctional assay (LIFA), which is fundamentally different. There was a significant linear relationship between the results from the two assays (r = 0.89, P = 0.001). The slope of the regression line was 0.65. In conclusion, this new convenient GHBP TR‐FIA provides a sensitive and precise method for detecting total GHBP as well as complexed GHBP in human serum, and allows easy processing of large numbers of samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2362.1996.2010558.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
FISKER, S., FRYSTYK, J., SKRIVER, L., VESTBO, E., HO, K. K. Y., & ØRSKOV, H.
Venue
European Journal of Clinical Investigation
Publisher
Wiley
Published
1996-09
Volume
26
Issue
9
Pages
779-785
ISSN
  • 0014-2972 (ISSN-L)
  • 1365-2362
OpenAlex
W2045151759
Cited by
69
References
0
FWCI
4.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simple, rapid immunometric assay for determination of functional and growth hormone‐occupied growth hormone‐binding protein in human serum. https://app.cochat.ai/papers/10.1046/j.1365-2362.1996.2010558.x
The paper
FISKER, S., FRYSTYK, J., SKRIVER, L., VESTBO, E., HO, K. K. Y., & ØRSKOV, H. (1996). A simple, rapid immunometric assay for determination of functional and growth hormone‐occupied growth hormone‐binding protein in human serum. European Journal of Clinical Investigation. https://doi.org/10.1046/j.1365-2362.1996.2010558.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.