Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Incidence of inhibitors in haemophilia A patients – a review of recent studies of recombinant and plasma‐derived factor VIII concentrates

Scharrer, Bray, Neutzling·1999·Haemophilia

Abstract

The development of inhibitors to factor VIII or IX is the most serious complication of haemophilia therapy. While early surveys revealed inhibitor prevalences of 3.6–25%, recent studies, especially those using recombinant DNA‐derived products, have prompted speculation as to whether ultrapurified products may cause a higher incidence of inhibitors. Although studies of ultrapure rFVIII in previously treated patients have not shown an increased inhibitor risk, in previously untreated patients (PUPs) with severe haemophilia A (factor VIII < 2%), cumulative incidences of approximately 30% have been reported. The majority of these inhibitors are low responders; many have disappeared spontaneously despite continued treatment with the study product (i.e. transient inhibitors), and were most probably detected as a consequence of frequent inhibitor testing. The mutation causing haemophilia has recently been shown to be a significant risk factor for developing an inhibitor; mutations leading to the absence of endogenous factor VIII protein (for example, large multidomain deletions, nonsense mutations, isochromosomal intron 22 inversions) are associated with the highest risk of inhibitor development. Furthermore, recent prospective studies of plasma‐derived products reveal inhibitor incidences (i.e. 21–52%) that are comparable to those obtained with recombinant products. When comparing the incidences of high‐responder inhibitors (> 10 BU) among recent prospectively studied severe haemophilia A cohorts (i.e. 11–41%), differences between plasma‐derived and recombinant products cannot be discerned. New studies of either recombinant or plasma‐derived products should consider all known parameters influencing inhibitor formation, thereby facilitating meaningful comparisons of inhibitor risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2516.1999.00300.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 200

Metadata

Authors
Scharrer, Bray, & Neutzling
Venue
Haemophilia
Publisher
Wiley
Published
1999-05
Volume
5
Issue
3
Pages
145-154
ISSN
  • 1351-8216 (ISSN-L)
  • 1365-2516
OpenAlex
W2157140221
Cited by
200
References
1
FWCI
5.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence of inhibitors in haemophilia A patients – a review of recent studies of recombinant and plasma‐derived factor VIII concentrates. https://app.cochat.ai/papers/10.1046/j.1365-2516.1999.00300.x
The paper
Scharrer, Bray, & Neutzling. (1999). Incidence of inhibitors in haemophilia A patients – a review of recent studies of recombinant and plasma‐derived factor VIII concentrates. Haemophilia. https://doi.org/10.1046/j.1365-2516.1999.00300.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.