MRI findings in haemophilic joints treated with radiosynoviorthesis with development of an MRI scale of joint damage
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We hypothesized that magnetic resonance imaging (MRI) scans taken prior to radiosynoviorthesis may be predictive of response to the procedure in persons with haemophilia. Specifically, response would be inversely related to the severity of synovial hyperplasia. Radiosynoviorthesis was administered to 21 joints with recurrent haemorrhage (target joints). A detailed self‐report of haemorrhage history, joint evaluation with scoring according to the World Federation of Haemophilia orthopaedic joint and pain scales, plain radiographs, and MRI studies of the joints were performed pre‐ and post‐radiosynoviorthesis. To augment comparison of the MRI findings to those assessed using the Arnold‐Hilgartner and Pettersson scales, a provisional MRI scale for evaluation of haemophilic arthropathy was designed. We found the MRI findings prior to the procedure were not predictive of clinical response; independent of the severity of synovial hyperplasia, most joints bled less and showed improvement by the WFH orthopaedic score. There was generally no change in the severity of synovial hyperplasia after the procedure. We conclude that MRI evaluation is not routinely indicated prior to radiosynoviorthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Twenty‐five years' experience of prophylactic treatment in severe haemophilia A and B
NILSSON, I. M., BERNTORP, E., LÖFQVIST, T., & PETTERSSON, H. (1992) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1992.tb00546.x · Cited by 961
Utility of magnetic resonance imaging for management of hemophilic arthropathy in children
Nuss, R., Kilcoyne, R. F., Geraghty, S. J., et al. (1993) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)81737-8 · Cited by 74
Self-citationConsiderations for current and future management of haemophilia and its complications
Lusher, J. M. (1995) · Haemophilia · doi:10.1111/j.1365-2516.1995.tb00032.x · Cited by 39
Idy-Peretti, I., Le Balc'h, T., Yvart, J., & Bittoun, J. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90374-9 · Cited by 28
Cited by
Prophylaxis versus episodic treatment to prevent joint disease in boys with severe hemophilia
Manco-Johnson, M. J., Abshire, T. C., Shapiro, A. D., Riske, B., Hacker, M. R., Kilcoyne, R., Ingram, J. D., Manco-Johnson, M. L., Funk, S., Jacobson, L., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067659 · Cited by 1,950
Self-citationHaemophilia and Joint Disease: Pathophysiology, Evaluation, and Management
Knobe, K., & Berntorp, E. (2011) · Journal of Comorbidity · doi:10.15256/joc.2011.1.2 · Cited by 178
Metadata
- Authors
- Nuss, R., Kilcoyne, R. F., Geraghty, S., Shroyer, A. L. W., Rosky, J. W., Mawhinney, S., Wiedel, J., & Manco‐Johnson, M.
- Venue
- Haemophilia
- Publisher
- Wiley
- Published
- 2000-05
- Volume
- 6
- Issue
- 3
- Pages
- 162-169
- ISSN
- 1351-8216 (ISSN-L)
- 1365-2516
- OpenAlex
- W2137516206
- Cited by
- 159
- References
- 4
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.