Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography

Bergmans, L., Van Cleynenbreugel, J., Wevers, M., Lambrechts, P. · 2001 · International Endodontic Journal

Abstract

Aim: The aim of this paper was to present an objective methodology for quantitative evaluation of root canal instrumentation using microcomputer tomography, together with developed software based on a constructed mathematical model. Methodology: A desktop X‐ray micro‐CT scanner (SkyScan 1072) was used to provide data sets of an extracted mandibular molar before and after instrumentation (ProFile 0.04 Taper instruments, Dentsply Maillefer, Ballaigues, Switzerland) that were stored for later use by software. A volume visualization package (T3D) was applied to obtain 3D renderings of the molar to illustrate the qualitative visualization capacity. Next, medical image volume fusion software was used to allow alignment of pre and post image volumes. Finally, software was developed to make quantitative measurements and to provide additional qualitative information on the registered image volumes. This procedure implemented a true 3D mathematical model for quantification of instrumentation effects. Using a local co‐ordinate frame, perpendicular reslices were made at five different levels within the mesio‐buccal canal to evaluate transportation and centring ability. Results: At first accurate and detailed 3D renderings were obtained. The general and local canal shape before and after preparation could visually be examined in 360° rotation. Numerical values were obtained for volume, volume changes and transportation. Centring ability was calculated by centring ratio and centre movement. Conclusions: This methodology is a new and objective way for quantitative evaluation of root canal instrumentation using microcomputer tomography and dedicated software.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2591.2001.00413.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 202

Metadata

Authors
Bergmans, L., Van Cleynenbreugel, J., Wevers, M., & Lambrechts, P.
Venue
International Endodontic Journal
Publisher
Wiley
Published
2001-07
Volume
34
Issue
5
Pages
390-398
ISSN
  • 0143-2885 (ISSN-L)
  • 1365-2591
OpenAlex
W2050408409
Cited by
202
References
1
FWCI
7.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography. https://app.cochat.ai/papers/10.1046/j.1365-2591.2001.00413.x
The paper
Bergmans, L., Van Cleynenbreugel, J., Wevers, M., & Lambrechts, P. (2001). A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography. International Endodontic Journal. https://doi.org/10.1046/j.1365-2591.2001.00413.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.