Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Progressive versus constant tapered shaft design using NiTi rotary instruments: Influence of NiTi shaft design

Open access
Bergmans, L., Van Cleynenbreugel, J., Beullens, M., Wevers, M., Van Meerbeek, B., Lambrechts, P. · 2003 · International Endodontic Journal

Abstract

AIM: To evaluate the influence of a progressive versus constant tapered shaft design on canal preparation by NiTi rotary techniques. METHODOLOGY: A XMCT-scanner and custom-made software were used to nondestructively analyse the mesial canals of 10 extracted mandibular molars in 3D with a spatial resolution of 12.5 microm. Specimens (n = 10 per group) were scanned before and after preparation using ProTaper (progressive tapered) or K3 (constant tapered) files. Numerical values for volume, curvature, dentine removal and centring ratio were obtained in addition to a visual inspection for canal aberrations. Data were analysed by (multiway factorial) anova, Wilcoxon tests and t-tests. RESULTS: The volume of total dentine removal (mean +/- SD) was 1.21 +/- 0.66 mm(3) (ProTaper) and 1.06 +/- 0.23 mm(3) (K3) (P > 0.05), and the amount of dentine removal at all separate horizontal regions examined was comparable for both groups. The mean linear dentine removal (transportation) was in the range of 8-212 microm (ProTaper) and 4-187 microm (K3). The resultant centring ratio varied from 0.01 to 0.24 (ProTaper) and from 0.01 to 0.17 (K3), whilst different straightening patterns were observed. A centre displacement towards the furcation coronally was most pronounced for the ProTaper group whereas a centre displacement towards the outer side of the curvature more apically was only observed for the K3 group. No severe canal aberrations were found. CONCLUSIONS: The progressive tapered shaft design of the ProTaper instrument was less influenced by the mid-root curvature than the constant tapered design of the K3 instrument thereby providing a good centred apical preparation. However, ProTaper instruments tended to transport towards the furcation in the coronal region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2591.2003.00650.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 211

Metadata

Authors
Bergmans, L., Van Cleynenbreugel, J., Beullens, M., Wevers, M., Van Meerbeek, B., & Lambrechts, P.
Venue
International Endodontic Journal
Publisher
Wiley
Published
2003-04
Volume
36
Issue
4
Pages
288-295
ISSN
0143-2885 (ISSN-L)
OpenAlex
W1974714182
Cited by
211
References
1
FWCI
12.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Progressive versus constant tapered shaft design using NiTi rotary instruments: Influence of NiTi shaft design. https://app.cochat.ai/papers/10.1046/j.1365-2591.2003.00650.x
The paper
Bergmans, L., Van Cleynenbreugel, J., Beullens, M., Wevers, M., Van Meerbeek, B., & Lambrechts, P. (2003). Progressive versus constant tapered shaft design using NiTi rotary instruments: Influence of NiTi shaft design. International Endodontic Journal. https://doi.org/10.1046/j.1365-2591.2003.00650.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.