CoChat

One explanation for the variability of the bacterial suspension test

Johnston, M. D., Simons, E. -A., Lambert, R. J. W. · 2000 · Journal of Applied Microbiology
Cited by 58

The DOI matches its Crossref record.

Abstract

Disinfection kinetic studies of sodium dodecyl sulphate, benzalkonium chloride and sodium hypochlorite against Staphylococcus aureus revealed that when a higher inoculum level of Staph. aureus than normal was used (approximately 1 log higher), the efficacy of disinfection was severely attenuated. Kinetic analysis using the Hom model for experiments carried out on tests using 3 x 108 organisms ml-1 were unable to account for the large increase in disinfection power observed when smaller inoculum levels were used. Since the inoculum was the same in every way except for the numbers used, the large variations in the log reduction/time curves could not be explained by a variation in the resistance of the population to the biocide, as identical log reduction-time curves should have resulted. The level of disinfection achieved for a given concentration of biocide was found to be approximately linearly related to the cell number ml-1 of test solution and not to the log number. The variation observed is believed to occur due to intrinsic self-quenching of the biocide by the microbes during the course of the disinfection test. As the level of free biocide decreases, the rate of reaction decreases, giving the tails of the log reduction/time curves. Such intrinsic self-quenching could explain the large variations known to occur in the legally required disinfection suspension tests.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2672.2000.00951.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Johnston, M. D., Simons, E. A., & Lambert, R. J. W.
Venue
Journal of Applied Microbiology
Published
2000-02
Volume
88
Issue
2
Pages
237-242
ISSN
  • 1364-5072 (ISSN-L)
  • 1365-2672
OpenAlex
W2013763637
Cited by
58
References
0
FWCI
3.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.