CoChat

A simple clinical model for the diagnosis of deep‐vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process

Open access
Wells, Hirsh, Anderson, Lensing, Foster, Kearon, Weitz, D'ovidio, Cogo, Prandoni, Girolami, Ginsberg · 1998 · Journal of Internal Medicine
Cited by 142

The DOI matches its Crossref record.

Abstract

Wells PS, Hirsh J, Anderson DR, Lensing AWA, Foster G, Kearon C, Weitz J, D'Ovidio R, Cogo A, Prandoni P, Girolami A, Ginsberg JS (Ottawa Civic Hospital, Ottawa, Hamilton Civic Hospitals Research Centre, Henderson General Hospital, and McMaster University, Hamilton, Ontario, and Victoria General Hospital, Nova Scotia, Canada; Instituto di Semeioti Medica, Padua, Italy; and Academic Medical Centre, Amsterdam, the Netherlands). A simple clinical model for the diagnosis of deep‐vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process. J Intern Med 1998; 243: 15–23. Objectives: We recently demonstrated the utility of a clinical model combined with ultrasonography to assist the diagnostic approach in patients with suspected deep‐vein thrombosis (DVT). In this study we also sought to demonstrate that the model is useful with impedance plethysmography, a less accurate and less utilized diagnostic test. The original clinical model is slightly cumbersome to use; thus at the completion of the study we attempted to develop a simpler scoring system with a goal of maintaining accuracy. Design: An open, nonrandomized, multicentre trial. Setting: Three centres, two in Canada, and one in Italy. Subjects: Ambulatory patients with suspected deep‐vein thrombosis. Interventions: All patients were assessed clinically to determine the probability for deep‐vein thrombosis prior to performing impedance plethysmography and venography. We compared the accuracy of impedance plethysmography between the three pretest probability categories of high, moderate and low. All of the above were performed and interpreted by independent observers. When the study was completed, we revised the clinical model by first performing a simple regression analysis then a multiple logistic regression analysis; a scoring system was devised using the latter. Results: Impedance plethysmography is significantly more sensitive and less specific for all DVT in patients with high pretest probability for deep‐vein thrombosis (P= 0.001). The post‐ test probability (positive predictive value) for deep‐vein thrombosis with an abnormal impedance plethysmography result was significantly different (P= 0.0001) between the three pretest probability categories. Multiple regression analysis has provided a new model with only nine variables and a simple scoring system. The retrospective application of the revised clinical model, which is simpler to use, suggests it will provide similar results as the original clinical model when combined with impedance plethysmography. The combination of impedance plethysmography and the clinical model suggests patients are likely to have false positive results if they have a low or moderate pretest probability for deep‐vein thrombosis and false negative results if the pretest probability is high. The combination of a low pretest probability and a normal impedance plethysmography result may exclude the need for serial testing, and represented more than 50% of our patient population. Conclusions: The use of the clinical model in conjunction with impedance plethysmography would decrease the number of false positive and negative diagnoses and could markedly decrease the need for serial impedance plethysmography. Combining the clinical model with impedance plethysmography could overcome the fact that impedance plethysmography is clearly less accurate than venous ultrasound imaging. The use of the revised clinical model may increase acceptability and utility, but prospective testing is required before widespread use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2796.1998.00249.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 142

Metadata

Authors
Wells, Hirsh, Anderson, Lensing, Foster, Kearon, Weitz, D'ovidio, Cogo, Prandoni, Girolami, & Ginsberg
Venue
Journal of Internal Medicine
Publisher
Wiley
Published
1998-01
Volume
243
Issue
1
Pages
15-23
ISSN
  • 0954-6820 (ISSN-L)
  • 1365-2796
OpenAlex
W2009283817
Cited by
142
References
0
FWCI
3.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simple clinical model for the diagnosis of deep‐vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process. https://app.cochat.ai/papers/10.1046/j.1365-2796.1998.00249.x
The paper
Wells, Hirsh, Anderson, Lensing, Foster, Kearon, Weitz, D'ovidio, Cogo, Prandoni, Girolami, & Ginsberg. (1998). A simple clinical model for the diagnosis of deep‐vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process. Journal of Internal Medicine. https://doi.org/10.1046/j.1365-2796.1998.00249.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.