Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record.

High‐resolution, energy‐dispersive microcalorimeter spectrometer for X‐ray microanalysis

WOLLMAN, D. A., IRWIN, K. D., HILTON, G. C., DULCIE, L. L., NEWBURY, D. E., MARTINIS, J. M.·1997·Journal of Microscopy

Abstract

We have developed a prototype X‐ray microcalorimeter spectrometer with high energy resolution for use in X‐ray microanalysis. The microcalorimeter spectrometer system consists of a superconducting transition‐edge sensor X‐ray microcalorimeter cooled to an operating temperature near 100 mK by a compact adiabatic demagnetization refrigerator, a superconducting quantum interference device current amplifier followed by pulse‐shaping amplifiers and pileup rejection circuitry, and a multichannel analyser with computer interface for the real‐time acquisition of X‐ray spectra. With the spectrometer mounted on a scanning electron microscope, we have achieved an instrument response energy resolution of better than 10 eV full width at half‐maximum (FWHM) over a broad energy range at real‐time output count rates up to 150 s−1. Careful analysis of digitized X‐ray pulses yields an instrument‐response energy resolution of 7.2 ± 0.4 eV FWHM at 5.89 keV for Mn Kα 1,2 X‐rays from a radioactive 55 Fe source, the best reported energy resolution for any energy‐dispersive detector.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2818.1997.2670824.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 241

Metadata

Authors
WOLLMAN, D. A., IRWIN, K. D., HILTON, G. C., DULCIE, L. L., NEWBURY, D. E., & MARTINIS, J. M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
1997-12
Volume
188
Issue
3
Pages
196-223
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2065413946
Cited by
241
References
0
FWCI
21.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐resolution, energy‐dispersive microcalorimeter spectrometer for X‐ray microanalysis. https://app.cochat.ai/papers/10.1046/j.1365-2818.1997.2670824.x
The paper
WOLLMAN, D. A., IRWIN, K. D., HILTON, G. C., DULCIE, L. L., NEWBURY, D. E., & MARTINIS, J. M. (1997). High‐resolution, energy‐dispersive microcalorimeter spectrometer for X‐ray microanalysis. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1997.2670824.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.