The DOI matches its Crossref record.
Contrast, resolution, pixelation, dynamic range and signal‐to‐noise ratio: fundamental limits to resolution in fluorescence light microscopy
Abstract
In a perfect optical system numerical aperture and wavelength determine resolution. In a real optical system, however, the number of photons collected from a specimen determines the contrast and this limits the resolution. Contrast is affected by the number of picture elements per unit area, the number of photons and the aberrations present in every optical system. The concept of contrast vs. distance functions is used to compare the resolution achievable in confocal and wide‐field fluorescence microscopes and the effect of a further reduction of the observable volume. In conclusio: (a) real optical systems will never be able to achieve the theoretical resolution, (b) wide‐field fluorescence microscopy will often provide a better resolution than confocal fluorescence microscopy, (c) decreasing the observed volume does not necessarily increase the resolution and (d) using multiple fluorophores can improve the accuracy with which distances are measured. Some numbers for typical situations are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-resolution Fourier-transform infrared chemical imaging with multiple synchrotron beams
Nasse, M. J., Walsh, M. J., Mattson, E. C., Reininger, R., Kajdacsy-Balla, A., Macias, V., Bhargava, R., & Hirschmugl, C. J. (2011) · Nature Methods · doi:10.1038/nmeth.1585 · Cited by 349
Quantitative Imaging with a Mobile Phone Microscope
Skandarajah, A., Reber, C. D., Switz, N. A., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096906 · Cited by 196
Metadata
- Authors
- Stelzer
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1998-01
- Volume
- 189
- Issue
- 1
- Pages
- 15-24
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2008674896
- Cited by
- 218
- References
- 0
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast, resolution, pixelation, dynamic range and signal‐to‐noise ratio: fundamental limits to resolution in fluorescence light microscopy. https://app.cochat.ai/papers/10.1046/j.1365-2818.1998.00290.x
- The paper
- Stelzer. (1998). Contrast, resolution, pixelation, dynamic range and signal‐to‐noise ratio: fundamental limits to resolution in fluorescence light microscopy. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1998.00290.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.