The DOI matches its Crossref record.
High resolution protein localization using soft X‐ray microscopy
Abstract
Soft X‐ray microscopes can be used to examine whole, hydrated cells up to 10 µm thick and produce images approaching 30 nm resolution. Since cells are imaged in the X‐ray transmissive ‘water window’, where organic material absorbs approximately an order of magnitude more strongly than water, chemical contrast enhancement agents are not required to view the distribution of cellular structures. Although living specimens cannot be examined, cells can be rapidly frozen at a precise moment in time and examined in a cryostage, revealing information that most closely approximates that in live cells. In this study, we used a transmission X‐ray microscope at photon energies just below the oxygen edge (λ = 2.4 nm) to examine rapidly frozen mouse 3T3 cells and obtained excellent cellular morphology at better than 50 nm lateral resolution. These specimens are extremely stable, enabling multiple exposures with virtually no detectable damage to cell structures. We also show that silver‐enhanced, immunogold labelling can be used to localize both cytoplasmic and nuclear proteins in whole, hydrated mammary epithelial cells at better than 50 nm resolution. The future use of X‐ray tomography, along with improved zone plate lenses, will enable collection of better resolution (approaching 30 nm), three‐dimensional information on the distribution of proteins in cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantum Dots as Cellular Probes
Alivisatos, A. P., Gu, W., & Larabell, C. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100432 · Cited by 1,366
Self-citationSoft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Sakdinawat, A., & Attwood, D. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.267 · Cited by 728
The cytotoxicity of cadmium-based quantum dots
Chen, N., He, Y., Su, Y., Li, X., Huang, Q., Wang, H., Zhang, X., Tai, R., & Fan, C. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.070 · Cited by 717
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Metadata
- Authors
- Meyer‐Ilse, W., Hamamoto, D., Nair, A., Lelièvre, S. A., Denbeaux, G., Johnson, L., Pearson, A. L., Yager, D., Legros, M. A., & Larabell, C. A.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2001-03
- Volume
- 201
- Issue
- 3
- Pages
- 395-403
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2111292986
- Cited by
- 197
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High resolution protein localization using soft X‐ray microscopy. https://app.cochat.ai/papers/10.1046/j.1365-2818.2001.00845.x
- The paper
- Meyer‐Ilse, W., Hamamoto, D., Nair, A., Lelièvre, S. A., Denbeaux, G., Johnson, L., Pearson, A. L., Yager, D., Legros, M. A., & Larabell, C. A. (2001). High resolution protein localization using soft X‐ray microscopy. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2001.00845.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.