The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The smooth fractionator
Abstract
Summary: A modification of the general fractionator sampling technique called the smooth fractionator is presented. It may be used in almost every situation in which sampling is performed from distinct items that are uniquely defined, often they are physically separated items or clusters like pieces, blocks, slabs, sections, etc. To each item is associated a ‘guesstimate’ or an associated variable with a more‐or‐less close – and possibly biased − relationship to the content of the item. The smooth fractionator is systematic sampling among the items arranged according to the guesstimates in a unique, symmetric sequence with one peak and minimal jumps. The smooth fractionator is both very simple to implement and so efficient that it should probably always be used unless the natural sequence of the sampling items is equally smooth. So far, there is no theory for the prediction of the efficiency of smooth fractionator designs in general, and their properties are therefore illustrated with a range of real and simulated examples. At the cost of a slightly more elaborate sampling scheme, it is, however, always possible to obtain an unbiased estimate of the real precision and of some of the variance components. The only real practical problem for always obtaining a high precision with the smooth fractionator is specimen inhomogeneity, but that is detectable at almost no extra cost. With careful designs and for sample sizes of about 10, the sampling variation for the primary, smooth fractionator sampling step may in practice often be small enough to be ignored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
West, M. J., Slomianka, L., & Gundersen, H. J. G. (1991) · The Anatomical Record · doi:10.1002/ar.1092310411 · Cited by 2,994
Self-citationThe efficiency of systematic sampling in stereology—reconsidered
GUNDERSEN, H. J. G., JENSEN, E. B. V., KIÊU, K., & NIELSEN, J. (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00457.x · Cited by 1,317
Self-citation
Cited by
Hsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
The Number of Alveoli in the Human Lung
Ochs, M., Nyengaard, J. R., Jung, A., Knudsen, L., Voigt, M., Wahlers, T., Richter, J., & Gundersen, H. J. G. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1107oc · Cited by 771
Self-citationNeocortical glial cell numbers in human brains
Pelvig, D. P., Pakkenberg, H., Stark, A. K., & Pakkenberg, B. (2008) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2007.04.013 · Cited by 601
How much is there really? Why stereology is essential in lung morphometry
Weibel, E. R., Hsia, C. C. W., & Ochs, M. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00808.2006 · Cited by 256
Armitage, J. A., Lakasing, L., Taylor, P. D., Balachandran, A. A., Jensen, R. I., Dekou, V., Ashton, N., Nyengaard, J. R., & Poston, L. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.084947 · Cited by 195
Metadata
- Authors
- Gundersen, H. J. G.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2002-09
- Volume
- 207
- Issue
- 3
- Pages
- 191-210
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2013931318
- Cited by
- 207
- References
- 2
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The smooth fractionator. https://app.cochat.ai/papers/10.1046/j.1365-2818.2002.01054.x
- The paper
- Gundersen, H. J. G. (2002). The smooth fractionator. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2002.01054.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.