The effects of digital filtering on mismatch negativity in wakefulness and slow‐wave sleep
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The mismatch negativity (MMN) is a response to a deviant auditory stimulus that occurs infrequently in a sequence of otherwise repetitive, homogeneous standard auditory stimuli. The MMN is presumed automatic and independent of conscious awareness. Recording of the MMN during unconscious states may be problematic. The frequency content of the long‐lasting MMN may overlap and summate with other event‐related slow potentials and low‐frequency background electroencephalogram (EEG) activity. The purpose of this study is to determine the optimal filter settings for recording the MMN during unconscious states. Auditory event‐related potentials (ERPs) were recorded from eight subjects in an oddball paradigm during wakefulness and Stages 3 and 4 of sleep [slow‐wave sleep (SWS)] using a 0.16–35 Hz analogue bandpass. Deviant probability was 0.033. Stimulus‐onset asynchrony was 150 ms. The EEG data were subsequently digitally filtered in the frequency domain. The low‐pass filter was set at either 24, 12 or 6 Hz, and the high‐pass filter at either 1, 2, 3 or 4 Hz. Applying a low‐pass filter down to 12 Hz had a minimal impact on the waking or sleeping MMN amplitude. On the other hand, increasing the high‐pass setting from 2 to 3 Hz permitted the visualization of the MMN recorded during sleep. The 4 Hz filter showed a similar trend but also markedly attenuated the amplitude of the waking MMN. A high‐pass setting of 3 Hz provides a reasonable compromise. It has only a slight effect on the MMN when the subject is conscious, but still attenuates most of the unwanted slow potential activity when the subject enters SWS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Decay time of the auditory sensory memory trace during wakefulness and REM sleep.
Atienza, M., Cantero, J. L., & Gómez, C. M. (2000) · Psychophysiology · doi:10.1111/1469-8986.3740485 · Cited by 54
Cited by
Role of Melatonin in the Regulation of Human Circadian Rhythms and Sleep
Cajochen, C., Kräuchi, K., & Wirz‐Justice, A. (2003) · Journal of Neuroendocrinology · doi:10.1046/j.1365-2826.2003.00989.x · Cited by 735
Neurophysiological Endophenotypes of Schizophrenia: The Viability of Selected Candidate Measures
Turetsky, B. I., Calkins, M. E., Light, G. A., Olincy, A., Radant, A. D., & Swerdlow, N. R. (2006) · Schizophrenia Bulletin · doi:10.1093/schbul/sbl060 · Cited by 567
Mismatch Negativity Deficits Are Associated With Poor Functioning in Schizophrenia Patients
Light, G. A., & Braff, D. L. (2005) · Archives of General Psychiatry · doi:10.1001/archpsyc.62.2.127 · Cited by 407
Preattentional and attentional cognitive deficits as targets for treating schizophrenia
Braff, D., & Light, G. (2004) · Psychopharmacology · doi:10.1007/s00213-004-1848-0 · Cited by 214
“Further support for the view of an attention-independent MMN comes from the fact that well-defined MMN waveforms can be observed in sleeping subjects (Sabri and Campbell 2002) and even comatose patients (Kane et al.”
BackgroundLight, G. A., Swerdlow, N. R., & Braff, D. L. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.10.1624 · Cited by 190
“In this context, it is striking that welldefined MMN waveforms can be obtained from fetuses using magnetoencephalography (Draganova et al., 2005), as well as from sleeping infants (Huotilainen et al., 2003; Cheour-Luhtanen et al., 1996; Alho, Sainio, Sajaniemi, Reinikainen, & Na ¨a ¨ta ¨nen, 1990) and adults ( Sabri &…”
Background
Metadata
- Authors
- Sabri, M., & Campbell, K. B.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 2002-05-24
- Volume
- 11
- Issue
- 2
- Pages
- 123-127
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W2048805245
- Cited by
- 43
- References
- 1
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.