CoChat

Mechanism of reaction of myeloperoxidase with hydrogen peroxide and chloride ion

Furtmüller, Paul G., Obinger, Christian, Hsuanyu, Yuchiong, Dunford, H. Brian · 2000 · European Journal of Biochemistry
Cited by 124

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The reaction of myeloperoxidase compound I (MPO‐I) with chloride ion is widely assumed to produce the bacterial killing agent after phagocytosis. Two values of the rate constant for this important reaction have been published previously: 4.7 × 10 6 m−1·s−1 measured at 25 °C [Marquez, L.A. and Dunford, H.B. (1995) J. Biol. Chem.270, 30434–30440], and 2.5 × 10 4 m−1·s−1 at 15 °C [Furtmüller, P.G., Burner, U. & Obinger, C. (1998) Biochemistry37, 17923–17930]. The present paper is the result of a collaboration of the two groups to resolve the discrepancy in the rate constants. It was found that the rate constant for the reaction of compound I, generated from myeloperoxidase (MPO) and excess hydrogen peroxide with chloride, decreased with increasing chloride concentration. The rate constant published in 1995 was measured over a lower chloride concentration range; the 1998 rate constant at a higher range. Therefore the observed conversion of compound I to native enzyme in the presence of hydrogen peroxide and chloride ion cannot be attributed solely to the single elementary reaction MPO‐I + Cl− → MPO + HOCl. The simplest mechanism for the overall reaction which fit the experimental data is the following: image image image where MPO‐I–Cl− is a chlorinating intermediate. We can now say that the 1995 rate constant is k2 and the corresponding reaction is rate‐controlling at low [Cl−]. At high [Cl−], the reaction with rate constant k3 is rate controlling. The 1998 rate constant for high [Cl−] is a composite rate constant, approximated by k2k3/k−2. Values of k1 and k−1 are known from the literature. Results of this study yielded k2 = 2.2 × 10 6 m−1·s−1, k−2 = 1.9 × 10 5 s−1 and k3 = 5.2 × 10 4 s−1. Essentially identical results were obtained using human myeloperoxidase and beef spleen myeloperoxidase.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1432-1327.2000.01491.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 124

Metadata

Authors
Furtmüller, P. G., Obinger, C., Hsuanyu, Y., & Dunford, H. B.
Venue
European Journal of Biochemistry
Publisher
Wiley
Published
2000-10
Volume
267
Issue
19
Pages
5858-5864
ISSN
  • 0014-2956 (ISSN-L)
  • 1432-1033
OpenAlex
W1517408457
Cited by
124
References
1
FWCI
1.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.