CoChat

Morphological, immunophenotypical and electrophysiological properties of resting microglia in vitro

Eder, Claudia, Schilling, Tom, Heinemann, Uwe, Haas, Dorit, Hailer, Nils, Nitsch, Robert · 1999 · European Journal of Neuroscience
Cited by 60

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Morphological, immunophenotypical and electrophysiological properties were investigated in isolated cultured murine microglia before and after exposure to astrocyte‐conditioned medium (ACM). Following application of ACM, microglial cells underwent a dramatic shape transformation from an amoeboid appearance to a ramified morphology. In parallel to morphological changes, a downregulation of macrophage surface antigens was observed in microglia exposed to ACM. Staining intensities for major histocompatibility complex (MHC) class II molecules and for the adhesion molecules leukocyte function‐associated antigen‐1 (LFA‐1) and intercellular adhesion molecule‐1 (ICAM‐1) were significantly decreased in ramified microglia 5 days after exposure to ACM. In microglial cells treated daily with ACM over a period of 5 days, the smallest staining intensities for all surface antigens as well as the smallest ramification index as a measure for the highest degree of ramification were determined. In addition, upregulation of delayed rectifier K + currents was observed in microglia exposed to ACM for 1 day or treated daily with ACM for 5 days. In contrast, untreated amoeboid microglia or ramified microglia analysed 5 days after exposure to ACM did not express delayed rectifier K + currents. Analyses of the resting membrane potential and expression levels and properties of inward rectifier K + currents did not reveal any differences between untreated and ACM‐treated microglia. It is suggested that electrophysiological properties of microglia do not strongly correlate with the morphology or the immunophenotype of microglial cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9568.1999.00852.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 60

Metadata

Authors
Eder, C., Schilling, T., Heinemann, U., Haas, D., Hailer, N., & Nitsch, R.
Venue
European Journal of Neuroscience
Publisher
Wiley
Published
1999-12
Volume
11
Issue
12
Pages
4251-4261
ISSN
  • 0953-816X (ISSN-L)
  • 1460-9568
OpenAlex
W2162693284
Cited by
60
References
1
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphological, immunophenotypical and electrophysiological properties of resting microglia in vitro. https://app.cochat.ai/papers/10.1046/j.1460-9568.1999.00852.x
The paper
Eder, C., Schilling, T., Heinemann, U., Haas, D., Hailer, N., & Nitsch, R. (1999). Morphological, immunophenotypical and electrophysiological properties of resting microglia in vitro. European Journal of Neuroscience. https://doi.org/10.1046/j.1460-9568.1999.00852.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.