CoChat

The Revised NASPE/BPEG Generic Code for Antibradycardia, Adaptive‐Rate, and Multisite Pacing

BERNSTEIN, ALAN D., DAUBERT, JEAN‐CLAUDE, FLETCHER, ROSS D., HAYES, DAVID L., LÜDERITZ, BERNDT, REYNOLDS, DWIGHT W., SCHOENFELD, MARK H., SUTTON, RICHARD · 2002 · Pacing and Clinical Electrophysiology
Cited by 323

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BERNSTEIN, A.D., et al.: The Revised NASPE/BPEG Generic Code for Antibradycardia, Adaptive‐Rate, and Multisite Pacing. In light of evolving pacemaker technology and increasing interest in multisite pacing, the Committee on the Development of Position Statements (CDPS) of the North American Society of Pacing and Electrophysiology (NASPE) created an ad hoc Pacemaker Mode Code Task Force in April 2001 under the chairmanship of David L. Hayes, MD, for the purpose of bringing the NASPE/British Pacing and Electrophysiology Group (BPEG) Generic Pacemaker Code (NBG Code) up to date. The task force, whose members are the authors of this article, designed a revised NBG Code in which three major issues were taken into account. First, it was recognized that all modern pacemaker pulse generators are capable of extensive bidirectional communication with an external programming device, making them “communicating” pulse generators as defined by the current (1987) NBG Code. Second, it was decided that a means of providing basic information regarding the location of multisite pacing would be a useful ingredient of the NBG Code. Third, in view of the extensive antibradycardia pacing capabilities common in modern implantable cardioverter defibrillators and the availability of the NASPE/BPEG Defibrillator Code (NBD Code), it was considered unnecessary for the NBG Code to address the presence or absence of antitachycardia features. The resulting updated version of the NBG Code as described herein was endorsed by the BPEG on September 20, 2001 and adopted by the NASPE Board of Trustees on October 18, 2001. The structure of the revised NBG Code differs from that of the previous version in two respects alone: Position IV specifies only the presence or absence of rate modulation, and Position V specifies only the location or absence of multisite pacing (i.e., biatrial or biventricular pacing with at least two stimulation sites in each case) more than one stimulation site in any single cardiac chamber, or any combination of these. The revised NBG Code is deliberately configured to avoid confusion with earlier mode codes, and it is the authors' hope that it will serve as an enhanced resource for communication among those engaged in every phase of the multidisciplinary practice of cardiac rhythm management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2002.00260.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 323

Metadata

Authors
BERNSTEIN, A. D., DAUBERT, J., FLETCHER, R. D., HAYES, D. L., LÜDERITZ, B., REYNOLDS, D. W., SCHOENFELD, M. H., & SUTTON, R.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2002-02
Volume
25
Issue
2
Pages
260-264
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2114326730
Cited by
323
References
3
FWCI
4.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Revised NASPE/BPEG Generic Code for Antibradycardia, Adaptive‐Rate, and Multisite Pacing. https://app.cochat.ai/papers/10.1046/j.1460-9592.2002.00260.x
The paper
BERNSTEIN, A. D., DAUBERT, J., FLETCHER, R. D., HAYES, D. L., LÜDERITZ, B., REYNOLDS, D. W., SCHOENFELD, M. H., & SUTTON, R. (2002). The Revised NASPE/BPEG Generic Code for Antibradycardia, Adaptive‐Rate, and Multisite Pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2002.00260.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.