CoChat

Efficacy of Metoprolol and Sotalol in the Prevention of Recurrences of Sustained Ventricular Tachyarrhythmias in Patients with an Implantable Cardioverter Defibrillator

KETTERING, KLAUS, MEWIS, CHRISTIAN, DÖRNBERGER, VOLKER, VONTHEIN, REINHARD, BOSCH, RALPH F., KÜHLKAMP, VOLKER · 2002 · Pacing and Clinical Electrophysiology
Cited by 69

The DOI matches its Crossref record.

Abstract

KETTERING, K., et al.: Efficacy of Metoprolol and Sotalol in the Prevention of Recurrences of Sustained Ventricular Tachyarrhythmias in Patients with an Implantable Cardioverter Defibrillator. ICDs provide protection against sudden cardiac death in patients with life‐threatening ventricular arrhythmias. Nevertheless, most ICD recipients receive adjunctive antiarrhythmic drug therapy to reduce the number of recurrent episodes and ICD discharges. The aim of the study was to compare the efficacy of metoprolol and d,l‐sotalol in preventing VT/VF recurrences in patients with an ICD in a prospective, randomized trial. One hundred patients (83 men, 17 women; mean age 59 years, SD ± 11 years) were randomized to receive metoprolol or sotalol after implantation of an ICD. There were no significant differences between the two groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The median follow‐up was 728 days (25th percentile: 530 days, 75th percentile: 943 days) in the metoprolol group and 727 days (25th percentile: 472 days, 75th percentile: 1,223 days) in the sotalol group (P = 0.52). Thirty‐three patients treated with metoprolol and 30 patients receiving sotalol had at least one episode during the follow‐up. Event‐free survival curves were generated for the two treatment arms using the Kaplan‐Meier method and showed no significant difference (P = 0.68). Eight patients treated with metoprolol and six patients treated with sotalol died during follow‐up. Total mortality was not significantly different between the two study groups (P = 0.43). Metoprolol is as efficacious as sotalol in preventing VT/VF recurrences in patients with an ICD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2002.01571.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
KETTERING, K., MEWIS, C., DÖRNBERGER, V., VONTHEIN, R., BOSCH, R. F., & KÜHLKAMP, V.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2002-11
Volume
25
Issue
11
Pages
1571-1576
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2091984080
Cited by
69
References
0
FWCI
2.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of Metoprolol and Sotalol in the Prevention of Recurrences of Sustained Ventricular Tachyarrhythmias in Patients with an Implantable Cardioverter Defibrillator. https://app.cochat.ai/papers/10.1046/j.1460-9592.2002.01571.x
The paper
KETTERING, K., MEWIS, C., DÖRNBERGER, V., VONTHEIN, R., BOSCH, R. F., & KÜHLKAMP, V. (2002). Efficacy of Metoprolol and Sotalol in the Prevention of Recurrences of Sustained Ventricular Tachyarrhythmias in Patients with an Implantable Cardioverter Defibrillator. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2002.01571.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.