Abstract

Risk stratification and effectiveness of implantable cardioverter‐defibrillator (ICD) therapy are unresolved issues in hypertrophic cardiomyopathy (HCM), a cardiac disease that is associated with arrhythmias and sudden death. We assessed ICD therapy in 132 patients with HCM: age at implantation was 34 ± 17 years , and 44 (33%) patients were aged ≤ 20 years . Indications were sustained ventricular tachycardia (VT) or cardiac arrest (secondary prevention) in 47 (36%) patients, and clinical features associated with increased risk for sudden death (primary prevention) in 85 (64%) patients. There were 6 deaths and 55 appropriate interventions in 27 (20%) patients during a mean follow‐up period of 4.8 ± 4.2 years : 5‐year survival and event‐free rates were 96%± 2% and 75%± 5% , respectively. ICD intervention‐free rates were significantly less for secondary than for primary prevention: 64%± 7% versus 84%± 6% at 5 years, P = 0.02 . Notably, 59 of 67 events (cardiac arrest and therapeutic ICD interventions), or 88%, occurred during sedentary or noncompetitive activity. Incidence of therapeutic shocks was related to age but not to other reported risk factors, including severity of cardiac hypertrophy, nonsustained VT during Holter monitoring, and abnormal blood pressure response to exercise. ICD related complications occurred in 38 (29%) patients, including 60 inappropriate ICD interventions in 30 (23%) patients. However, 8 (27%) of the patients with inappropriate shocks also had therapeutic interventions. ICD is effective for secondary prevention of sudden death in HCM. However, selection of patients for primary prevention of sudden death, and prevention of device related complications require further refinement. (PACE 2003; 26:1887–1896)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.00285.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 123

Metadata

Authors
BEGLEY, D. A., MOHIDDIN, S. A., TRIPODI, D., WINKLER, J. B., & FANANAPAZIR, L.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-08-21
Volume
26
Issue
9
Pages
1887-1896
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1981961005
Cited by
123
References
0
FWCI
4.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of Implantable Cardioverter Defibrillator Therapy for Primary and Secondary Prevention of Sudden Cardiac Death in Hypertrophic Cardiomyopathy. https://app.cochat.ai/papers/10.1046/j.1460-9592.2003.00285.x
The paper
BEGLEY, D. A., MOHIDDIN, S. A., TRIPODI, D., WINKLER, J. B., & FANANAPAZIR, L. (2003). Efficacy of Implantable Cardioverter Defibrillator Therapy for Primary and Secondary Prevention of Sudden Cardiac Death in Hypertrophic Cardiomyopathy. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2003.00285.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.