Cited by 62Cardiovascular Syncope and Autonomic DisordersCardiac electrophysiology and arrhythmiasHeart Rate Variability and Autonomic Control

Diagnostic yield of external electrocardiographic loop recorders in patients with recurrent syncope and negative tilt table test

SCHUCHERT, ANDREAS, MAAS, RENKE, KRETZSCHMAR, CHRISTINA, BEHRENS, GINA, KRATZMANN, INGRID, MEINERTZ, THOMAS·2003·Pacing and Clinical Electrophysiology

Abstract

External electrocardiographic loop recording permits extended cardiac rhythm monitoring and ECG storage before and after device activation. The purpose of the study was to assess the diagnostic yield of external loop recorders in patients with more than two syncopal events within the last 6 months and a negative tilt table test. Twenty-four consecutive patients (51 +/- 14 years, male n = 9) were enrolled with 3 +/- 4 recurrent syncopal events within the last 6 months and no overt structural heart disease. The loop recorder CardioCall continuously records a two-channel ECG via skin electrodes. When activated, up to 4.5 minutes of the ECG preceding activation is stored. The time between tilt table testing and monitoring was 5 +/- 4 weeks. The average monitoring period covered 50 +/- 22 days. Recording was either unsuccessful or terminated prematurely in 5 patients. The reasons were skin irritation secondary to the electrodes in two patients, cable damage in one patient, and two patients inadvertently erased the stored data when replacing the batteries. Fourteen patients activated the loop recorder at least once. Symptoms leading to device activation were syncope (n = 1), dizziness (n = 11), feeling unwell (n = 7), palpitations (n = 5), headaches (n = 1), and chest pain (n = 1). The loop recorder documented sinus tachycardia during the syncopal event. Sinus tachycardia was also observed in 7 other patients, and atrial flutter in two patients. Eight patients had recurrent syncope with two patients experiencing syncope prior to the monitoring period, one syncope occurred in a patient who inadvertently erased the stored data, one event coincided with sinus tachycardia, and 4 (17%) patients had syncope during 15 +/- 10 months after termination of loop monitoring. The external loop recorder was not very useful for arrhythmia detection in patients with syncopal events, no overt heart disease, and a negative tilt table test because the cardiac rhythm was stored in only 1 of 8 (13%) patients with recurrent syncope. Reasons for the low diagnostic yield of external loop recorders were infrequent syncopal events after the baseline evaluation, with rare events during the limited monitoring period in particular, and premature termination or unsuccessful recording in 21% of patients.

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.t01-1-00277.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • External loop recorders can be useful in patients with relatively frequent syncope episodes.

    “External loop recorders can be useful in patients with relatively frequent syncope episodes. 166-168”

The citation lists haven’t been fetched yet

References 20 · Cited by 62

Authors
SCHUCHERT, A., MAAS, R., KRETZSCHMAR, C., BEHRENS, G., KRATZMANN, I., & MEINERTZ, T.
Affiliations
Universität Hamburg (DE)
Corresponding author
SCHUCHERT, ANDREAS
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-08-21
Volume
26
Issue
9
Pages
1837-1840
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2057841900
Cited by
62
References
20
Citations by year
2025: 1 · 2021: 3 · 2019: 2 · 2018: 4 · 2017: 1 · 2016: 3 · 2015: 4 · 2014: 4 · 2013: 6 · 2012: 3
FWCI
3.20
Type
journal article
Language
en
Open access
closed
Locations
  • Pacing and Clinical Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
recurrent syncope, diagnostic yield, sinus tachycardia, atrial flutter, arrhythmia detection, device activation
MeSH terms
Arrhythmias, Cardiac, Electrocardiography, Female, Humans, Male, Middle Aged, Time Factors, Electrocardiography, Ambulatory, Tilt-Table Test, Syncope, Vasovagal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review