Cited by 23Diabetes Management and ResearchDiabetes Treatment and ManagementPancreatic function and diabetes

Physiological responses during hypoglycaemia induced by regular human insulin or a novel human analogue, insulin glargine

Dagogo‐Jack, S., Askari, H., Morrill, B., Lehner, L. L., Kim, B., Sha, X.·2000·Diabetes, Obesity and Metabolism

Abstract

SUMMARY Aim Glargine, a product of recombinant technology, has different structural and physico‐chemical properties compared with native human insulin. We determined whether such differences are associated with alterations in the responses to hypoglycaemia induced by glargine. Methods Nineteen adults (six healthy and 13 with type 1 diabetes) underwent a 5‐h hyperinsulinaemic (2 mU/kg/min −1 ) stepped hypoglycaemic clamps (hourly targets of 4.7, 4.2, 3.6, 3.1 and 2.5 mmol/l, respectively) on two occasions using intravenous infusion of regular human insulin or glargine, in random sequence. Hypoglycaemic symptoms, counter‐regulatory hormones and glucose disposal rates were assessed at intervals throughout the clamps. A 1‐week ‘wash out’ period was observed between studies. Results The peak total symptoms scores (mean ± s.e.m.) at nadir blood glucose (2.5 mmol/l) were 18.83 ± 2.68 (healthy) and 17.46 ± 3.62 (diabetic) during regular insulin, and 18.50 ± 3.20 (healthy) and 19.08 ± 3.83 (diabetic) during glargine infusion. The peak epinephrine levels during hypoglycaemia were 767.8 ± 140.4 pg/ml (regular insulin) and 608.8 ± 129.9 pg/ml (glargine) among healthy subjects, and 332.5 ± 54.8 pg/ml (regular insulin) and 321.8 ± 67.4 pg/ml (glargine) in diabetic patients. Diabetic patients had blunted glucagon responses during hypoglycaemia with either insulin. Both insulins also elicited similar rates of glucose disposal. Conclusions We conclude that insulin glargine and regular human insulin elicit comparable symptomatic and counter‐regulatory hormonal responses during hypoglycaemia in healthy or diabetic subjects, and induce similar rates of glucose disposal. Since glargine is designed for subcutaneous (s.c.) use, it is possible (though unlikely) that our findings obtained using an intravenous protocol could differ from responses to hypoglycaemia induced by the s.c. route.

Integrity signals

Registry

Crossref · 10.1046/j.1463-1326.2000.00109.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 29 · Cited by 23

Authors
Dagogo‐Jack, S., Askari, H., Morrill, B., Lehner, L. L., Kim, B., & Sha, X.
Affiliations
  • Washington University in St. Louis (US)
  • Hoechst Marion Roussel (United States) (US)
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2000-12
Volume
2
Issue
6
Pages
373-383
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W1965068429
Cited by
23
References
29
Citations by year
2023: 1 · 2022: 1 · 2020: 1 · 2018: 1 · 2017: 1 · 2013: 1
FWCI
2.66
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Obesity and Metabolism (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • American Diabetes Association
  • National Institutes of Health (5p60dk020579-35)
  • National Institute of Diabetes and Digestive and Kidney Diseases (2P60-DK-20579)
  • National Center for Research Resources (MO1RR00036, M01RR000036)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
insulin glargine, regular insulin, hypoglycemia, counterregulatory hormones, epinephrine, glucagon, glucose disposal, hypoglycaemic symptoms, type 1 diabetes, long-acting insulin analogues, subcutaneous insulin administration
MeSH terms
Insulin Glargine, Adult, Blood Glucose, Blood Pressure, C-Peptide, Diabetes Mellitus, Type 1, Double-Blind Method, Epinephrine, Female, Glucagon, Heart Rate, Humans, Hydrocortisone, Hyperinsulinism, Hypoglycemia, Insulin, Male, Norepinephrine, Recombinant Proteins, Reference Values, Glucose Clamp Technique, Cross-Over Studies, Human Growth Hormone, Insulin, Long-Acting

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review