Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 224

The DOI matches its Crossref record.

Multicentre comparison of skin hydration in terms of physical‐, physiological‐ and product‐dependent parameters by the capacitive method (Corneometer CM 825)

Open access
Heinrich, U., Koop, U., Leneveu‐Duchemin, M.‐C., Osterrieder, K., Bielfeldt, S., Chkarnat, C., Degwert, J., Häntschel, D., Jaspers, S., Nissen, H.‐P., Rohr, M., Schneider, G., Tronnier, H. · 2003 · International Journal of Cosmetic Science

Abstract

Synopsis: A multicentre study for measuring skin hydration with 349 volunteers was carried out in six different laboratories. The purpose of the study was to investigate physical‐, physiological‐ and product‐dependent parameters of three test emulsions (base, base + moisturizer and base + moisturizer + lipids) in a double‐blind study. A comparison between analogous and digital sensor technology of the Corneometer CM825 was examined. Here, a clear relationship between both sensor types could be highlighted. A vital point of the study was the division of the test subjects according to their skin type. To get more objective limits for three different skin types – very dry, dry and normal skin – visual expert evaluation, self‐assessment and hydration measurements were analysed by means of statistical methods. The moisture‐related skin types were determined as follows: very dry skin was characterized with corneometer units below 30, dry skin between 30 and 40 and normal skin higher than 40 a.u. (arbitrary units). The efficacy of the three test emulsions was examined in relation to the mentioned skin types. Analysing the measured data of all test centres, a clear dependency of skin physiology (skin type) and product efficacy became evident. The drier the skin, the higher the increase of hydration. The product performance of the three test emulsions compared to the untreated control resulted in a significant increase of skin hydration in all measuring centres. The evaluation of a product ranking showed a good differentiation between the basic emulsion and the two other products. An increase of efficacy by adding lipids could be observed in four of six centres. The important influence of the skin type of the volunteers on the degree of product performance, as demonstrated in this study, should be especially considered when drawing up guidelines for efficacy testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1467-2494.2003.00172.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 224

Metadata

Authors
Heinrich, U., Koop, U., Leneveu‐Duchemin, M. ‐., Osterrieder, K., Bielfeldt, S., Chkarnat, C., Degwert, J., Häntschel, D., Jaspers, S., Nissen, H. ‐., Rohr, M., Schneider, G., & Tronnier, H.
Venue
International Journal of Cosmetic Science
Publisher
Wiley
Published
2003-04
Volume
25
Issue
1-2
Pages
45-53
ISSN
  • 0142-5463 (ISSN-L)
  • 1468-2494
OpenAlex
W1972086614
Cited by
224
References
0
FWCI
0.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multicentre comparison of skin hydration in terms of physical‐, physiological‐ and product‐dependent parameters by the capacitive method (Corneometer CM 825). https://app.cochat.ai/papers/10.1046/j.1467-2494.2003.00172.x
The paper
Heinrich, U., Koop, U., Leneveu‐Duchemin, M. ‐., Osterrieder, K., Bielfeldt, S., Chkarnat, C., Degwert, J., Häntschel, D., Jaspers, S., Nissen, H. ‐., Rohr, M., Schneider, G., & Tronnier, H. (2003). Multicentre comparison of skin hydration in terms of physical‐, physiological‐ and product‐dependent parameters by the capacitive method (Corneometer CM 825). International Journal of Cosmetic Science. https://doi.org/10.1046/j.1467-2494.2003.00172.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.