CoChat

Characterization of placenta accreta using transvaginal sonography and color Doppler imaging

Open access
Lerner, J. P., Deane, S., Timor‐Tritsch, I. E. · 1995 · Ultrasound in Obstetrics & Gynecology
Cited by 148

The DOI matches its Crossref record.

Abstract

The safe use of transvaginal sonography in patients with placenta previa has been confirmed, and has revolutionized precise placental localization. The aim of our study was to evaluate the efficacy of transvaginal sonography and color‐coded blood flow in the prediction of placenta accreta. Twenty‐one patients with persistent placenta previa were scanned using transvaginal sonography and color‐coded flow. Suspicion for placenta accreta consisted of total placenta previa at term with several placental lacunae exhibiting marked or turbulent blood flow, as seen with color Doppler transvaginal sonography from within the placenta, extending into the surrounding tissues. Five of the patients exhibited sonographic placental patterns suspicious for placenta accreta and one patient exhibited placental and cervical blood flow described as lacunar. Five Cesarean hysterectomies were performed for placenta accreta. Every placenta accreta was correctly diagnosed sonographically by the use of color flow studies. One patient with suspicion of placenta accreta delivered at another institution, a Cesarean hysterectomy was performed, and the pathology was confirmed. The one placenta previa exhibiting turbulent lacunar flow in the cervical area only was not confirmed to be an accreta at Cesarean section, although hemostasis was difficult at the placental bed. The remaining 15 patients with placenta previa and who on sonography were not suspicious for placenta accreta underwent uncomplicated Cesarean section. Transvaginal sonography and color Doppler imaging improve the diagnostic accuracy in the prediction of placenta accreta in patients with persistent placenta previa. A pattern of turbulent blood flow extending from the placenta into the surrounding tissues should alert the physician to the possibility of placenta accreta. Copyright © 1995 International Society of Ultrasound in Obstetrics and Gynecology

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1469-0705.1995.05030198.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 148

Metadata

Authors
Lerner, J. P., Deane, S., & Timor‐Tritsch, I. E.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
1995-03
Volume
5
Issue
3
Pages
198-201
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2011863298
Cited by
148
References
0
FWCI
4.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of placenta accreta using transvaginal sonography and color Doppler imaging. https://app.cochat.ai/papers/10.1046/j.1469-0705.1995.05030198.x
The paper
Lerner, J. P., Deane, S., & Timor‐Tritsch, I. E. (1995). Characterization of placenta accreta using transvaginal sonography and color Doppler imaging. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.1995.05030198.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.