Transvaginal ultrasonographic characterization of ovarian masses: comparison of five scoring systems in a multicenter study
The DOI matches its Crossref record.
Abstract
The aim of this work was to test and compare the accuracy of five different morphological scoring systems to identify malignant ovarian masses in a prospective multicenter study. Four of the systems had previously been reported by Granberg, Sassone, De Priest and Lerner and the fifth is newly developed. A total of 330 ovarian neoplasms were collected in three different centers, which adopted the same diagnostic procedures. Of these, 261 masses were benign (mean diameter 50 ± 26 mm) and 69 were malignant (mean diameter 69 ± 33 mm) (prevalence 21%). The area under the receiver operating characteristic (ROC) curve for the multicenter score was 0.84. This was significantly better than the areas of the other four scores which ranged from 0.72 to 0.75. The cut‐off levels derived from the five ROC curves achieved a sensitivity that ranged from 74% (Sassone score) to 88% (De Priest score ≥ 5), and a specificity from 40% (De Priest) to 67% (multicenter); the highest positive predictive value was 41% (multicenter). With a cut‐off level of 9, the accuracy of the multicenter score was significantly better than the scores of Granberg and De Priest (McNemar's test p < 0.0001). Similar results were obtained in 207 ovarian masses of ≤ 5 cm in mean diameter, and when 19 borderline and 11 stage 1 cancers only were considered. For the clinical purposes of a screening test we also checked a possible cut‐off level of ≥ 8, which increased the sensitivity to 93% with a drop of specificity to 56%. With the use of the same criteria for the scores of the different authors, the following values were obtained for sensitivity: 96%, 81%, 93% and 90%; and for specificity: 23%, 56%, 28% and 49%. The multicenter score performed well at distinguishing malignant from benign lesions, and was better than the other four traditional scores, for both large and small masses. This was mainly due to the introduction of two criteria that allowed correction for typical dermoids and endohemorrhagic corpora lutea. A completely reliable differentiation of benign from malignant masses cannot be obtained by sonographic imaging alone. Copyright © 1997 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simple ultrasound-based rules for the diagnosis of ovarian cancer
Timmerman, D., Testa, A. C., Bourne, T., Ameye, L., Jurkovic, D., Van Holsbeke, C., Paladini, D., Van Calster, B., Vergote, I., Van Huffel, S., et al. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5365 · Cited by 613
“diameter of at least 100 mm; and (5) very high color content on color Doppler examination.”
BackgroundTimmerman, D., Ameye, L., Fischerova, D., Epstein, E., Melis, G. B., Guerriero, S., Van Holsbeke, C., Savelli, L., Fruscio, R., Lissoni, A. A., et al. (2010) · BMJ · doi:10.1136/bmj.c6839 · Cited by 478
Progress and Challenges in Screening for Early Detection of Ovarian Cancer
Jacobs, I. J., & Menon, U. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r400006-mcp200 · Cited by 458
Imaging Evaluation of Ovarian Masses
Jeong, Y.-Y., Outwater, E. K., & Kang, H. K. (2000) · RadioGraphics · doi:10.1148/radiographics.20.5.g00se101445 · Cited by 410
Cache Template Attacks: Automating Attacks On Inclusive Last-Level Caches
Gruss, D., Spreitzer, R., & Mangard, S. (2015) · INFM-OAR (INFN Catania) · doi:10.5281/zenodo.55454 · Cited by 317
Nossov, V., Amneus, M., Su, F., Lang, J., Janco, J. M. T., Reddy, S. T., & Farias-Eisner, R. (2008) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2008.04.009 · Cited by 291
Kaijser, J., Sayasneh, A., Van Hoorde, K., Ghaem-Maghami, S., Bourne, T., Timmerman, D., & Van Calster, B. (2014) · Human Reproduction Update · doi:10.1093/humupd/dmt059 · Cited by 218
“Seven of them (Sassone, Lerner, Depriest, Ferrazzi, Tailor, RMI I to II) had already been extensively evaluated in the previous systematic review (Jacobs et al., 1990; Sassone et al., 1991; DePriest et al., 1993; Lerner et al., 1994; Tingulstad et al., 1996; Ferrazzi et al., 1997; Tailor et al., 1997).”
BackgroundCohen, L. S., Escobar, P. F., Scharm, C., Glimco, B., & Fishman, D. A. (2001) · Gynecologic Oncology · doi:10.1006/gyno.2001.6253 · Cited by 203
Ovarian Cancer, the Revised FIGO Staging System, and the Role of Imaging
Javadi, S., Ganeshan, D. M., Qayyum, A., Iyer, R. B., & Bhosale, P. (2016) · American Journal of Roentgenology · doi:10.2214/ajr.15.15199 · Cited by 203
“Ultrasound relies on morphologic features to distinguish between benign and malignant lesions; features such as thick irregular walls, papillary projections, and solid echogenic locules are considered signs of malignancy [25–28].”
BackgroundAsymptomatic Adnexal Masses: Correlation of FDG PET and Histopathologic Findings
Fenchel, S., Grab, D., Nuessle, K., Kotzerke, J., Rieber, A., Kreienberg, R., Brambs, H.-J., & Reske, S. N. (2002) · Radiology · doi:10.1148/radiol.2233001850 · Cited by 201
Kaijser, J., Bourne, T., Valentin, L., Sayasneh, A., Van Holsbeke, C., Vergote, I., Testa, A. C., Franchi, D., Van Calster, B., & Timmerman, D. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12323 · Cited by 197
“The 12 variables used in LR1 were: (1) personal history of ovarian cancer; (2) current hormonal therapy; (3) age of the patient; (4) maximum diameter of the lesion; (5) pain during examination; (6) ascites; (7) blood flow within a solid papillary projection; (8) a purely solid tumor; (9) the maximum diameter of the so…”
MethodCastellucci, P., Perrone, A. M., Picchio, M., Ghi, T., Farsad, M., Nanni, C., Messa, C., Meriggiola, M. C., Pelusi, G., Al-Nahhas, A., et al. (2007) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3281afa256 · Cited by 192
The Accuracy of Risk Scores in Predicting Ovarian Malignancy: A Systematic Review
Geomini, P., Kruitwagen, R., Bremer, G. L., Cnossen, J., & Mol, B. W. J. (2009) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e318195ad17 · Cited by 184
The diagnostic value of PET/CT for primary ovarian cancer—A prospective study
RISUM, S., HOGDALL, C., LOFT, A., BERTHELSEN, A., HOGDALL, E., NEDERGAARD, L., LUNDVALL, L., & ENGELHOLM, S. (2007) · Gynecologic Oncology · doi:10.1016/j.ygyno.2006.11.022 · Cited by 171
“The sensitivity of US for detecting OC has been found to range from 71% to 96% and the corresponding specificity has been found to range from 23% to 83% [1,5,9,14].”
BackgroundThe role of magnetic resonance imaging and ultrasound in patients with adnexal masses
Sohaib, S. A., Mills, T. D., Sahdev, A., Webb, J. A. W., VanTrappen, P. O., Jacobs, I. J., & Reznek, R. H. (2005) · Clinical Radiology · doi:10.1016/j.crad.2004.09.007 · Cited by 171
Metadata
- Authors
- Ferrazzi, E., Zanetta, G., Dordoni, D., Berlanda, N., Mezzopane, R., & Lissoni, G.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 10
- Issue
- 3
- Pages
- 192-197
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2028572629
- Cited by
- 172
- References
- 0
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.