Antenatal diagnosis of velamentous umbilical cord insertion and vasa previa with color Doppler imaging
The DOI matches its Crossref record.
Abstract
Objective: To determine whether cord insertion can be consistently visualized and whether velamentous cord insertion and vasa previa can be consistently identified with color Doppler imaging during routine sonography in the mid‐trimester. Design: A prospective study. Subjects: A total of 587 fetuses at 18–20 weeks' gestation. Methods: During routine ultrasound examinations, the sonographer was instructed to take additional time and to image the placental cord insertion with color Doppler imaging and classify this as normal, velamentous or ‘not seen’. When the insertion was velamentous, the sonographer was instructed to indicate whether or not it was vasa previa. The sonogram obtained at 18–20 weeks' gestation was used for comparison with outcome data. Results: Cord insertion was visualized by color Doppler imaging in 99.8% (586/587) of the fetuses in our study. The mean time required for examination was 20 s and, in 95% of the cases, cord insertion was visualized within 1 min. The sonographic identification of velamentous cord insertion had a sensitivity of 100% (5/5), a specificity of 99.8% (580/581), a positive predictive value of 83% (5/6) and a negative predictive value of 100% (580/580). In our study, vasa previa was diagnosed at 18 gestational weeks in two cases and, in one of the cases, vasa previa was confirmed at delivery. Conclusions: We could consistently identify cord insertion and velamentous cord insertion with color Doppler imaging during routine sonography in the mid‐trimester. Transvaginal color Doppler imaging and serial scans were needed to identify vasa previa. Copyright © 1999 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Placenta Previa, Placenta Accreta, and Vasa Previa
Oyelese, Y., & Smulian, J. C. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000207559.15715.98 · Cited by 975
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Vasa Previa: The Impact of Prenatal Diagnosis on Outcomes
Oyelese, Y., Catanzarite, V., Prefumo, F., Lashley, S., Schachter, M., Tovbin, Y., Goldstein, V., & Smulian, J. C. (2004) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000123245.48645.98 · Cited by 394
Sepulveda, W., Rojas, I., Robert, J. A., Schnapp, C., & Alcalde, J. L. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.132 · Cited by 273
Prenatal ultrasound diagnosis of vasa praevia and analysis of risk factors
Baulies, S., Maiz, N., Muñoz, A., Torrents, M., Echevarría, M., & Serra, B. (2007) · Prenatal Diagnosis · doi:10.1002/pd.1753 · Cited by 188
“Placental cord insertion is easily identifiable in almost all cases by means of colour Doppler, and this procedure extends the ultrasound examination time by less than a minute (Sepulveda et al., 2003; Nomiyama et al., 1998).”
Metadata
- Authors
- Nomiyama, M., Toyota, Y., & Kawano, H.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 1998-12
- Volume
- 12
- Issue
- 6
- Pages
- 426-429
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2030915588
- Cited by
- 144
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antenatal diagnosis of velamentous umbilical cord insertion and vasa previa with color Doppler imaging. https://app.cochat.ai/papers/10.1046/j.1469-0705.1998.12060426.x
- The paper
- Nomiyama, M., Toyota, Y., & Kawano, H. (1998). Antenatal diagnosis of velamentous umbilical cord insertion and vasa previa with color Doppler imaging. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.1998.12060426.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.