Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record.

Selective versus non‐selective laser photocoagulation of placental vessels in twin‐to‐twin transfusion syndrome

Quintero, R. A., Comas, C., Bornick, P. W., Allen, M. H., Kruger, M.·2000·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: We have recently described a surgical technique for the treatment of twin‐to‐twin transfusion syndrome (TTTS) that allows precise identification of vascular anastomoses (selective laser photocoagulation of communicating vessels, or S‐LPCV). The purpose of this study was to compare S‐LPCV with the previous non‐selective technique (NS‐LPCV) that targeted all vessels crossing the dividing membrane. Materials and Methods: Patients with TTTS were treated with NS‐LPCV from May 1994 to June 1997 and with S‐LPCV from July 1997 to December 1999. TTTS was defined as polyhydramnios of ≥8 cm maximum vertical pocket (MVP) in the recipient twin and oligohydramnios of ≤2 cm MVP in the donor twin. Outcome was measured as survival per number of pregnancies and per number of fetuses together with limited morbidity data. Results: NS‐LPCV was used in 18 patients and 74 were treated with S‐LPCV. Three patients interrupted their pregnancies electively after surgery (S‐LPCV) and were removed from further analysis. Survival of at least one fetus was higher in S‐LPCV (83.1%) than in NS‐LPCV (61.1%) (P = 0.04), mostly due to a lower rate of dual intra‐uterine fetal demise in S‐LPCV (5.6%) than in NS‐LPCV (22%) (P = 0.05). There were more hydropic fetuses in the NS‐LPCV group (27%) than in the S‐LPCV group (5.4%), but this difference did not account for the results. There was no difference in the survival per number of fetuses between the two groups. Conclusions: S‐LPCV represents an important evolution in the surgical treatment of TTTS. The use of this technique by all centers should allow better comparison of fetal survival and morbidity rates. S‐LPCV should be the standard technique in trials comparing amniocentesis versus laser for the treatment of severe TTTS. Copyright © 2000 International Society of Ultrasound in Obstetrics and Gynecology

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1469-0705.2000.00265.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
Quintero, R. A., Comas, C., Bornick, P. W., Allen, M. H., & Kruger, M.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2000-09
Volume
16
Issue
3
Pages
230-236
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2014889952
Cited by
205
References
0
FWCI
7.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selective versus non‐selective laser photocoagulation of placental vessels in twin‐to‐twin transfusion syndrome. https://app.cochat.ai/papers/10.1046/j.1469-0705.2000.00265.x
The paper
Quintero, R. A., Comas, C., Bornick, P. W., Allen, M. H., & Kruger, M. (2000). Selective versus non‐selective laser photocoagulation of placental vessels in twin‐to‐twin transfusion syndrome. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.2000.00265.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.