The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bone adaptation to load: microdamage as a stimulus for bone remodelling
Open accessAbstract
Mechanical loading in the proximal radius was increased by ulnar osteotomy (Group O), altered by Steinmann pinning (Group P) or unaltered in sham operated controls (Group C) in skeletally mature female sheep, aged 2–4 years. A series of intravenous fluorochromes were given to label bone formation and fuchsin‐stained microdamage assessed at intervals of up to 24 weeks. Microcracks were present in all groups and were found in the original cortex near the periosteal surface. No microcracks were found in the new, fibrolamellar bone laid down at periosteal or endosteal surfaces. Mean microcrack length (49 µm, SD 10 µm) did not differ between groups or over time. Microcrack numerical and surface densities and resorption cavity density peaked in all groups at 6 weeks, consistent with a regional acceleratory phenomenon (RAP), but the peaks were significantly greater in Group O. The density of refilling or secondary osteons peaked at 10 weeks and the mean time required for the formation of an osteon was 7.51 ± 0.59 weeks. Fatigue‐induced microdamage is normally present in bone and is increased due to repetitive loading of the mechanically overloaded radius. The location and timing of microcracks, resorption cavities and secondary osteons are consistent with the activation‐resorption‐formation remodelling cycle and suggest that microdamage is a stimulus for bone remodelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verborgt, O., Gibson, G. J., & Schaffler, M. B. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.1.60 · Cited by 731
Cited by
The aging of Wolff’s “law”: Ontogeny and responses to mechanical loading in cortical bone
Pearson, O. M., & Lieberman, D. E. (2004) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20155 · Cited by 745
Living with cracks: Damage and repair in human bone
Taylor, D., Hazenberg, J. G., & Lee, T. C. (2007) · Nature Materials · doi:10.1038/nmat1866 · Cited by 375
Self-citationMechanistic aspects of fracture and R-curve behavior in human cortical bone
Nalla, R. K., Kruzic, J. J., Kinney, J. H., & Ritchie, R. O. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.017 · Cited by 342
Bone remodelling in humans is load-driven but not lazy
Christen, P., Ito, K., Ellouz, R., Boutroy, S., Sornay-Rendu, E., Chapurlat, R. D., & van Rietbergen, B. (2014) · Nature Communications · doi:10.1038/ncomms5855 · Cited by 281
Basis of bone metabolism around dental implants during osseointegration and peri‐implant bone loss
Insua, A., Monje, A., Wang, H., & Miron, R. J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36060 · Cited by 277
Metadata
- Authors
- Lee, T. C., Staines, A., & Taylor, D.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2002-12
- Volume
- 201
- Issue
- 6
- Pages
- 437-446
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2084546241
- Cited by
- 225
- References
- 1
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bone adaptation to load: microdamage as a stimulus for bone remodelling. https://app.cochat.ai/papers/10.1046/j.1469-7580.2002.00123.x
- The paper
- Lee, T. C., Staines, A., & Taylor, D. (2002). Bone adaptation to load: microdamage as a stimulus for bone remodelling. Journal of Anatomy. https://doi.org/10.1046/j.1469-7580.2002.00123.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.