Fractionated Plasma Separation and Adsorption System: A Novel System for Blood Purification to Remove Albumin Bound Substances
Abstract
The removal of albumin bound substances has gained increasing interest in different diseases, especially in acute and chronic liver disease. Therefore, a new system, the fractionated plasma separation and adsorption (FPSA) system, was developed based on combined membrane and adsorbent blood purification techniques. The most important contribution to the FPSA system was the development of a new polysulfone hollow‐fiber filter, which is characterized by a sieving coefficient of 0.89 for human serum albumin (HSA) but only of 0.17 for fibrinogen, and 0 (zero) for IgM immunoglobulins. Using a closed filtrate circuit connected to the new polysulfone filter which integrates 1 or 2 adsorption columns and also a high flux dialyzer adapted to a dialysis machine, the FPSA system opens excellent possibilities for the relatively specific removal of albumin bound substances from the blood such as albumin bound bilirubin or even tryptophan. In comparison to other systems (for example, the Molecular Adsorbent Recirculating System [MARS] and albumin dialysis systems), the FPSA system enables much higher elimination of strongly bound albumin substances. The first clinical investigations have recently started based on a modified dialysis machine designed with all necessary safety measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lee, W. M., Stravitz, T. R., & Larson, A. M. (2012) · Hepatology · doi:10.1002/hep.25551 · Cited by 550
Prometheus® – a new extracorporeal system for the treatment of liver failure☆
Rifai, K., Ernst, T., Kretschmer, U., Bahr, M. J., Schneider, A., Hafer, C., Haller, H., Manns, M. P., & Fliser, D. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(03)00468-9 · Cited by 291
Uremic Toxicity: Present State of the Art
Vanholder, R., Argilés, A., Baurmeister, U., Brunet, P., Clark, W., Cohen, G., Dedeyn, P. P., Deppisch, R., Descamps-Latscha, B., Henle, T., et al. (2001) · The International Journal of Artificial Organs · doi:10.1177/039139880102401004 · Cited by 281
Artificial liver support systems: what is new over the last decade?
García Martínez, J. J., & Bendjelid, K. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0453-z · Cited by 137
Rifai, K., Hafer, C., Rosenau, J., Athmann, C., Haller, H., Peter Manns, M., & Fliser, D. (2006) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365520600610154 · Cited by 53
Metadata
- Authors
- Falkenhagen, D., Strobl, W., Vogt, G., Schrefl, A., Linsberger, I., Gerner, F. J., & Schoenhofen, M.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 1999-01
- Volume
- 23
- Issue
- 1
- Pages
- 81-86
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2097773191
- Cited by
- 240
- References
- 0
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fractionated Plasma Separation and Adsorption System: A Novel System for Blood Purification to Remove Albumin Bound Substances. https://app.cochat.ai/papers/10.1046/j.1525-1594.1999.06292.x
- The paper
- Falkenhagen, D., Strobl, W., Vogt, G., Schrefl, A., Linsberger, I., Gerner, F. J., & Schoenhofen, M. (1999). Fractionated Plasma Separation and Adsorption System: A Novel System for Blood Purification to Remove Albumin Bound Substances. Artificial Organs. https://doi.org/10.1046/j.1525-1594.1999.06292.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.