The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Molecular Adsorbents Recycling System as a Liver Support System Based on Albumin Dialysis: A Summary of Preclinical Investigations, Prospective, Randomized, Controlled Clinical Trial, and Clinical Experience from 19 Centers
Open accessAbstract
Abstract: Artificial liver support aims to prolong survival time of patients with liver failure by detoxification. Albumin as a molecular adsorbent in dialysis solution is capable of attracting even tightly albumin‐bound toxins from blood into the dialysate if a specific dialysis membrane is used and if the albumin's binding sites are on‐line‐purified by a sorbent/dialysis‐based recycling system (i.e., molecular adsorbents recycling system, or MARS). The MARS technology has been shown to remove water‐soluble and albumin‐bound toxins and to provide renal support in case of renal failure. Fourteen centers have reported that MARS treatment improved mental status of patients with liver failure and hepatic encephalopathy. In treating liver failure and cholestasis, MARS was associated with hemodynamic stabilization, improvement of hepatic and kidney function, and disappearance of pruritus. In hepatic failure and hepatorenal syndrome, a prospective, randomized, controlled trial of MARS treatment was able to prolong survival time significantly. MARS has been used in 26 patients with acute liver failure or primary graft dysfunction. Nineteen centers reporting on 103 patients have shown that MARS treatment is safe, easy to handle, feasible, and effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide circulates in mammalian plasma primarily as an S-nitroso adduct of serum albumin.
Stamler, J. S., Jaraki, O., Osborne, J., Simon, D. I., Keaney, J., Vita, J., Singel, D., Valeri, C. R., & Loscalzo, J. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.16.7674 · Cited by 1,238
Cited by
Acute liver failure: Summary of a workshop†
Lee, W. M., Squires, R. H., Nyberg, S. L., Doo, E., & Hoofnagle, J. H. (2008) · Hepatology · doi:10.1002/hep.22177 · Cited by 757
Hassanein, T. I., Tofteng, F., Brown, R. S., McGuire, B., Lynch, P., Mehta, R., Larsen, F. S., Gornbein, J., Stange, J., & Blei, A. T. (2007) · Hepatology · doi:10.1002/hep.21930 · Cited by 407
Self-citationOettl, K., & Stauber, R. E. (2007) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707251 · Cited by 357
Advances in bioartificial liver devices
Allen, J. W., Hassanein, T., & Bhatia, S. N. (2001) · Hepatology · doi:10.1053/jhep.2001.26753 · Cited by 326
Self-citationPrometheus® – a new extracorporeal system for the treatment of liver failure☆
Rifai, K., Ernst, T., Kretschmer, U., Bahr, M. J., Schneider, A., Hafer, C., Haller, H., Manns, M. P., & Fliser, D. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(03)00468-9 · Cited by 291
Metadata
- Authors
- Stange, J., Hassanein, T. I., Mehta, R., Mitzner, S. R., & Bartlett, R. H.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 2002-02
- Volume
- 26
- Issue
- 2
- Pages
- 103-110
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2042484524
- Cited by
- 206
- References
- 1
- FWCI
- 16.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Molecular Adsorbents Recycling System as a Liver Support System Based on Albumin Dialysis: A Summary of Preclinical Investigations, Prospective, Randomized, Controlled Clinical Trial, and Clinical Experience from 19 Centers. https://app.cochat.ai/papers/10.1046/j.1525-1594.2002.06822.x
- The paper
- Stange, J., Hassanein, T. I., Mehta, R., Mitzner, S. R., & Bartlett, R. H. (2002). The Molecular Adsorbents Recycling System as a Liver Support System Based on Albumin Dialysis: A Summary of Preclinical Investigations, Prospective, Randomized, Controlled Clinical Trial, and Clinical Experience from 19 Centers. Artificial Organs. https://doi.org/10.1046/j.1525-1594.2002.06822.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.