CoChat

Clinically significant allo-anti-I in an I-negative patient with massive hemorrhage

Chaplin, H., Hunter, V. L., Malecek, A. C., Kilzer, P., Rosche, M. E. · 1986 · Transfusion
Cited by 14

The DOI matches its Crossref record.

Abstract

A 37‐year‐old white man who had never been transfused was admitted as an emergency patient with a ruptured spleen and a falling hematocrit (19% on admission). All crossmatches were incompatible. His serum contained anti‐I, and his red cells (RBCs) were I‐negative and strongly i‐positive. Only 4 units of crossmatch‐compatible I‐negative frozen RBCs were available immediately. Because of the likelihood that more than 4 units would be required, chromium survival studies were performed using I‐positive cells. Samples obtained at 15 and 30 minutes after injection revealed less than 1 percent survival of the donor RBCs. He received the 4 units of I‐negative RBCs during the operation in addition to reinfusion of RBCs harvested from 1800 ml of blood aspirated from the abdominal cavity. The postoperative hematocrit remained greater than 30 percent and the bilirubin less than 1.5 mg per dl. Before recommending frozen storage of autologous RBCs, 51 Cr labeled I‐positive RBCs from the patient's daughter (obligate li heterozygote) were infused. Survival was 100 percent at 15 and 30 minutes, 90 percent at 3 hours, 85 percent at 26 hours; the remaining RBCs disappeared at a normal rate (T½2 27 days) over the succeeding 2 weeks. A repeat 51 Cr‐labeled RBC study with the original I‐positive donor confirmed greater than 92 percent destruction in 90 minutes. The clinical significance of this allo‐anti‐I (apparently primarily against RBCs from homozygous I‐positive donors) is in marked contrast to reported findings with auto‐anti‐I antibodies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1537-2995.1986.26186124032.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 11

  1. 10.1111/j.1423-0410.1963.tb04147.x · doi:10.1111/j.1423-0410.1963.tb04147.x
  2. 10.1172/JCI105764 · doi:10.1172/jci105764
  3. 10.7326/0003-4819-44-2-221 · doi:10.7326/0003-4819-44-2-221
  4. Pruzanki W., 1974, Clinical and immunochemical studies of IgM cold agglutinins with lambda type light chains, Clin Immunol Immunopathol, 2, 234, 10.1016/0090-1229(74)90041-5 · doi:10.1016/0090-1229(74)90041-5
  5. 10.1111/j.1423-0410.1971.tb01799.x · doi:10.1111/j.1423-0410.1971.tb01799.x
  6. 10.1111/j.1423-0410.1976.tb04647.x · doi:10.1111/j.1423-0410.1976.tb04647.x
  7. 10.1046/j.1537-2995.1980.20380214890.x · doi:10.1046/j.1537-2995.1980.20380214890.x
  8. 10.1046/j.1537-2995.1983.23483276869.x · doi:10.1046/j.1537-2995.1983.23483276869.x
  9. 10.1172/JCI108547 · DOI
  10. 10.1111/j.1423-0410.1960.tb04667.x · doi:10.1111/j.1423-0410.1960.tb04667.x
  11. 10.3109/08820138109050693 · DOI

Cited by

See all 14

Metadata

Authors
Chaplin, H., Hunter, V. L., Malecek, A. C., Kilzer, P., & Rosche, M. E.
Venue
Transfusion
Publisher
Wiley
Published
1986-01-02
Volume
26
Issue
1
Pages
57-61
ISSN
  • 0041-1132
  • 1537-2995
Cited by
14
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinically significant allo-anti-I in an I-negative patient with massive hemorrhage. https://app.cochat.ai/papers/10.1046/j.1537-2995.1986.26186124032.x
The paper
Chaplin, H., Hunter, V. L., Malecek, A. C., Kilzer, P., & Rosche, M. E. (1986). Clinically significant allo-anti-I in an I-negative patient with massive hemorrhage. Transfusion. https://doi.org/10.1046/j.1537-2995.1986.26186124032.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.