CoChat

Transfusion transmission of retroviruses: human T‐lymphotropic virus types I and II compared with human immunodeficiency virus type 1

Donegan, E., Lee, H., Operskalski, E.A., Shaw, G.M., Kleinman, S.H., Busch, M.P., Stevens, C.E., Schiff, E.R., Nowicki, M.J., Hollingsworth, C.G., Mosley, J.W., The Transfusion Safety Study Group · 1994 · Transfusion
Cited by 145

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: The incidence of transfusion transmission of human T‐ lymphotropic virus type I (HTLV‐I) and HTLV type II (HTLV‐II) has not been compared directly or to that of human immunodeficiency virus type 1 (HIV‐1). The effects of refrigerator storage of the blood component on infectivity of the viruses needs definition. Study Design and Methods: The circumstances influencing the transmission of HTLV‐I, HTLV‐ II, and HIV‐1 via blood of donors whose sera were stored in a repository and who were retrospectively documented as having been infected at blood donation were examined. Confirmation and typing of anti‐HTLV positivity in donors and recipients used polymerase chain reaction, supplemented by specific peptide testing. Results: Overall, 27 percent (26/95) of the recipients of blood components from anti‐HTLV‐ I‐ and ‐II‐positive donors became infected (9 with HTLV‐I and 17 with HTLV‐II). No recipients of acellular blood components became infected with HTLV‐I or ‐II. There was no probable transmission by components stored > 10 days. The rates of transmission for both viruses were similar: 0 to 5 days' storage, 17 (74%) of 23; 6 to 10 days, 8 (44%) of 18; and 11 to 14, 0 (0%) of 10 (trend, p = 0.0002). In comparison, 89 percent (112/126) of the recipients of anti‐HIV‐1‐positive blood were infected regardless of component type, and no effect on transmission occurred with storage for < 26 days. Conclusion: Transfusion‐ transmitted HTLV‐I and ‐II are similar. The data suggest that a donor's lymphocytes become noninfectious when they lose the ability to be activated or to proliferate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1537-2995.1994.34694295061.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 145

Metadata

Authors
Donegan, E., Lee, H., Operskalski, E. A., Shaw, G. M., Kleinman, S. H., Busch, M. P., Stevens, C. E., Schiff, E. R., Nowicki, M. J., Hollingsworth, C. G., Mosley, J. W., & The Transfusion Safety Study Group
Venue
Transfusion
Publisher
Wiley
Published
1994-06
Volume
34
Issue
6
Pages
478-483
ISSN
  • 0041-1132 (ISSN-L)
  • 1537-2995
OpenAlex
W2077628697
Cited by
145
References
1
FWCI
2.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transfusion transmission of retroviruses: human T‐lymphotropic virus types I and II compared with human immunodeficiency virus type 1. https://app.cochat.ai/papers/10.1046/j.1537-2995.1994.34694295061.x
The paper
Donegan, E., Lee, H., Operskalski, E. A., Shaw, G. M., Kleinman, S. H., Busch, M. P., Stevens, C. E., Schiff, E. R., Nowicki, M. J., Hollingsworth, C. G., Mosley, J. W., & The Transfusion Safety Study Group. (1994). Transfusion transmission of retroviruses: human T‐lymphotropic virus types I and II compared with human immunodeficiency virus type 1. Transfusion. https://doi.org/10.1046/j.1537-2995.1994.34694295061.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.