Cited by 155

Liquid nitrogen freezers: a potential source of microbial contamination of hematopoietic stem cell components

Fountain, D, Ralston, M, Higgins, N, Gorlin, JB, Uhl, L, Wheeler, C, Antin, JH, Churchill, WH +1 more·1997·Transfusion

Abstract

BACKGROUND: The recent report of hepatitis B transmission between hematopoietic progenitor and putative stem cell (HPC) components stored in liquid nitrogen led to the questioning of whether evidence existed for similar contamination by bacterial or fungal elements. STUDY DESIGN AND METHODS: Microbial contamination rates were reviewed for 704 HPC components from 255 patients over an 18‐month period. Five liquid nitrogen freezers were surveyed for microbial contamination. The literature was reviewed to ascertain the published experience of other laboratories with HPC component contamination first documented on thawing. RESULTS: Seven (1.2%) of 583 thawed components were found to be contaminated with a variety of environmental or waterborne organisms, despite a meticulous protocol to prevent contamination during thawing. All of these components had been sterile on cryopreservation. Literature review revealed a similar incidence of post‐thaw contamination from other centers. Microbial survey of liquid nitrogen freezers revealed low‐level contamination in four of five. The organisms represented were similar to those cultured from thawed HPC components. One freezer was heavily contaminated by Aspergillus species. CONCLUSION: Liquid nitrogen freezers are not sterile, and both the liquid and vapor phases are potential sources of microbial contamination of HPC components. While low‐level contamination by environmental organisms may be common, the occurrence of heavy contamination by potential pathogens such as Aspergillus species suggests that monitoring of liquid nitrogen sterility may be indicated. Strategies to assess and prevent microbial transmission from liquid nitrogen to HPC components need further development.

Integrity signals

Registry

Crossref · 10.1046/j.1537-2995.1997.37697335152.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Potential sources of viral contamination include the operator, cell culture reagents of animal origin, cells or tissues of human origin (including feeder cells), and even contamination derived from liquid nitrogen storage vessels.

    “In cell culture, there are also various potential sources of viral contamination, including the operator, cell culture reagents of animal origin, cells or tissues of human origin (including feeder cells), and even contamination derived from liquid nitrogen storage vessels (Fountain et al., 1997; Grout and Morris, 2009; Morris, 2005).”

    From Guidance document on Good cell and tissue culture practice 2.0 (GCCP 2.0) (2021) · cites this paper as Fountain et al., 1997

Cited by

Authors
Fountain, D., Ralston, M., Higgins, N., Gorlin, J., Uhl, L., Wheeler, C., Antin, J., Churchill, W., & Benjamin, R.
Venue
Transfusion
Publisher
Wiley
Published
1997-06
Volume
37
Issue
6
Pages
585-591
ISSN
  • 0041-1132
  • 1537-2995
Cited by
155
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review