HPC viability measurement: trypan blue versus acridine orange and propidium iodide
The DOI matches its Crossref record.
Abstract
BACKGROUND: A reliable, validated method for rapidly determining HPC viability is essential for clinical cell engineering. STUDY DESIGN AND METHODS: A fluorometric cell viability assay using acridine orange and propidium iodide (AO/PI) was compared to the current standard, trypan blue (TB) exclusion. Viable cells stained with AO/PI fluoresce green under darkfield fluorescence microscopy, while nonviable cells fluoresce orange. Mixtures of fresh and heat‐killed bone marrow were prepared and used as viability standards for evaluation of both assays. The frequency of CFU‐GM was determined for each specimen. RESULTS: Cell viability measured by AO/PI was extremely linear, with measured and predicted viability in agreement from 0 to 100 percent of the viable cells and a coefficient of regression (r 2) of 0.9921. The predicted‐viability regression line fell within the 95% CI for AO/PI‐measured viability. The coefficient of regression for TB‐measured viability was 0.9584, with the predicted‐viability regression line almost entirely outside the 95% CI. TB overestimated the percentage of viable cells, particularly below the 50‐percent level. CFU‐GM frequency correlated better with cell viability measured by AO/PI (r 2 = 0.979) than with that measured by TB (r 2 = 0.930). CONCLUSIONS: The AO/PI viability assay is a rapid, highly linear, functionally correlated assay that is superior to conventional viability measurement by TB exclusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ExtraPEG: A Polyethylene Glycol-Based Method for Enrichment of Extracellular Vesicles
Rider, M. A., Hurwitz, S. N., & Meckes, D. G. (2016) · Scientific Reports · doi:10.1038/srep23978 · Cited by 695
Toxicity of Nanomaterials: Exposure, Pathways, Assessment, and Recent Advances
Ganguly, P., Breen, A., & Pillai, S. C. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00068 · Cited by 341
Effects of ursolic acid and oleanolic acid on human colon carcinoma cell line HCT15
Li, J. (2002) · World Journal of Gastroenterology · doi:10.3748/wjg.v8.i3.493 · Cited by 215
Guidelines for the automated evaluation of Elispot assays
Janetzki, S., Price, L., Schroeder, H., Britten, C. M., Welters, M. J. P., & Hoos, A. (2015) · Nature Protocols · doi:10.1038/nprot.2015.068 · Cited by 88
“ crItIcal The use of methods based on trypan blue incorporation does not allow the discrimination of apoptotic cells and may lead to an overestimation of living cells 46 .”
MethodStroncek, D. F., Jin, P., McKenna, D. H., Takanashi, M., Fontaine, M. J., Pati, S., Schäfer, R., Peterson, E., Benedetti, E., & Reems, J.-A. (2020) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2020.00458 · Cited by 59
“For example, it would be advantageous for the MSC field to promote the use of superior methods like automated cell counts and the use of fluorescent dyes for viability testing over that of manual cell counts and the use of trypan blue for viability assessments to characterize whole BM aspirates prior to culture initia…”
MethodCell wall protection by the Candida albicans class I chitin synthases
Preechasuth, K., Anderson, J. C., Peck, S. C., Brown, A. J. P., Gow, N. A. R., & Lenardon, M. D. (2015) · Fungal Genetics and Biology · doi:10.1016/j.fgb.2015.08.001 · Cited by 43
Metadata
- Authors
- Mascotti, K., McCullough, J., & Burger, S. R.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2000-06
- Volume
- 40
- Issue
- 6
- Pages
- 693-696
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2164278547
- Cited by
- 195
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.