Catheter Ablation of Atrial Flutter Guided by Electroanatomic Mapping (CARTO): A Randomized Comparison to the Conventional Approach
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electroanatomic vs Conventional Mapping for Atrial Flutter Ablation. Introduction: Three‐dimensional electroanatomic (CARTO) activation mapping of the cavotricuspid isthmus can be helpful to guide atrial flutter ablation, but to date has not heen investigated in comparison to conventional strategies. The aim of the present study was to assess the efficacy of the CARTO navigation system, especially with respect to the fluoroscopy time required for successful atrial flutter ablation. Methods and Results: Eighty patients with recurrent common‐type atrial flutter were randomly assigned to temperature‐controlled radiofrequency (RF) catheter ablation, either guided by conventional criteria (group 1) or additionally oriented on electroanatomic mapping (group 2). In all patients, similar multipolar catheters were inserted into the coronary sinus and placed at the tricuspid annulus. respectively. In group 2, positioning of the mapping electrode and delivery of RF pulses within the cavotricuspid isthmus was mainly oriented on the CARTO map to achieve the most linear and continuous RF lesions. Abolition of intra‐atrial conduction verified by conventional criteria (group 1) and electroanatomic mapping (group 2) could be verified in all patients. The overall number of RF pulses (group 1: 16.7 ± 6.5; group 2: 13.2 ± 5.3) and mean procedure duration (group 1: 172.5 ± 47.4 min; group 2: 169.3 ± 47.3 min) were not different between the two groups, but mean fluoroscopy time was significantly shorter when the CARTO tecbnology was used (group 1: 29.2 ± 9.4 min; group 2: 7.7 ± 2.8 min; F = 0.0001). Recurrence of atrial flutter was observed in 3 (9%) patients in each group after a mean follow‐up of 8.5 ± 2.months. Conclusion: Atrial flutter can be abolished effectively using the conventional technique as well as oriented on electroanatomic mapping. However, overall X‐ray exposure can he significantly reduced by the CARTO‐guided approach without prolongation of procedure duration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schwartzman, D., Callans, D. J., Gottlieb, C. D., Dillon, S. M., Movsowitz, C., & Marchlinski, F. E. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00345-2 · Cited by 197
Cited by
Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Pérez, F. J., Schubert, C. M., Parvez, B., Pathak, V., Ellenbogen, K. A., & Wood, M. A. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.871665 · Cited by 303
BlomstromLundqvist, C. (2003) · European Heart Journal · doi:10.1016/j.ehj.2003.08.002 · Cited by 263
Earley, M. J., Showkathali, R., Alzetani, M., Kistler, P. M., Gupta, D., Abrams, D. J., Horrocks, J. A., Harris, S. J., Sporton, S. C., & Schilling, R. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi834 · Cited by 201
“2 min.(4,11) In another trial of 40 patients using NavX, a comparable reduction was found (24.”
Metadata
- Authors
- WILLEMS, S., WEISS, C., VENTURA, R., RÜPPEL, R., RISIUS, T., HOFFMANN, M., & MEINERTZ, T.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 11
- Issue
- 11
- Pages
- 1223-1230
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2090850952
- Cited by
- 112
- References
- 1
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Catheter Ablation of Atrial Flutter Guided by Electroanatomic Mapping (CARTO): A Randomized Comparison to the Conventional Approach. https://app.cochat.ai/papers/10.1046/j.1540-8167.2000.01223.x
- The paper
- WILLEMS, S., WEISS, C., VENTURA, R., RÜPPEL, R., RISIUS, T., HOFFMANN, M., & MEINERTZ, T. (2000). Catheter Ablation of Atrial Flutter Guided by Electroanatomic Mapping (CARTO): A Randomized Comparison to the Conventional Approach. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2000.01223.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.