The DOI matches its Crossref record.
Do Current Dual Chamber Cardioverter Defibrillators Have Advantages Over Conventional Single Chamber Cardioverter Defibrillators in Reducing Inappropriate Therapies? A Randomized, Prospective Study
Open accessAbstract
Dual Chamber vs Single Chamber Cardioverter Defibrillators. Introduction: Supraventricular tachyarrhythmias are the main cause of inappropriate therapies in patients with conventional single chamber implantable cardioverter defibrillators (VVI‐ICD). It was anticipated that dual chamber cardioverter defibrillators (DDD‐ICD), with their capacity to analyze atrial and ventricular rhythm, could substantially reduce inappropriate therapies. Methods and Results: Our prospective study included 92 patients (87 men; mean age 61 ± 12.7 years) who were randomly assigned to a VVI‐ICD (45 patients) or a DDD‐ICD (47 patients). Both groups were followed for 7.5 ± 3.5 and 7.6 ± 4.1 months, respectively. During the follow‐up period, overall 725 ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes were recorded in 45 (49%) of 92 patients. Of these episodes, 404 (56%) occurred in the VVI‐ICD group and 321 (44%) episodes occurred in the DDD‐ICD group. Twenty‐three (51%) patients in the VVI‐ICD group and 22 (47%) patients in the DDD‐ICD group (P = 0.8) developed VT/VF. Overall, 73 (10%) of 725 treated episodes were inappropriate in 6 (13%) patients in the VVI group and in 10 (21%) patients in the DDD‐ICD group (P = 0.2). There were 22 (31%) inappropriately treated episodes in the VVI‐ICD group and 51 (69%) in the DDD‐ICD group. Thirty‐two of the 51 inappropriate episodes in the DDD‐ICD patients resulted from intermittent atrial sensing problems that led to failure of the respective dual chamber algorithms. Nonfatal complications occurred in 6 (13%) patients in the VVI‐ICD group and in 3 (6%) patients in the DDD‐ICD group (P = 0.7). Conclusion: We conclude that the implanted DDD‐ICD and conventional VVI‐ICD are equally safe and effective for therapy of life‐threatening ventricular tachyarrhythmias. Although DDD‐ICDs allow better rhythm classification, the applied detection algorithms do not offer benefits in avoiding inappropriate therapies during supraventricular tachyarrhythmias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318223e2bd · Cited by 2,104
2020 ESC guidelines on sports cardiology and exercise in patients with cardiovascular disease
Pelliccia, A., Sharma, S., Gati, S., Bäck, M., Börjesson, M., Caselli, S., Collet, J.-P., Corrado, D., Drezner, J. A., Halle, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa605 · Cited by 1,958
2011 ACCF/AHA Guideline for the Diagnosis and Treatment of Hypertrophic Cardiomyopathy
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.011 · Cited by 1,276
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
Inappropriate Implantable Cardioverter-Defibrillator Shocks
van Rees, J. B., Borleffs, C. J. W., de Bie, M. K., Stijnen, T., van Erven, L., Bax, J. J., & Schalij, M. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.059 · Cited by 451
Metadata
- Authors
- DEISENHOFER, I., KOLB, C., NDREPEPA, G., SCHREIECK, J., KARCH, M., SCHMIEDER, S., ZRENNER, B., & SCHMITT, C.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2001-02
- Volume
- 12
- Issue
- 2
- Pages
- 134-142
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2106024820
- Cited by
- 248
- References
- 0
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Do Current Dual Chamber Cardioverter Defibrillators Have Advantages Over Conventional Single Chamber Cardioverter Defibrillators in Reducing Inappropriate Therapies? A Randomized, Prospective Study. https://app.cochat.ai/papers/10.1046/j.1540-8167.2001.00134.x
- The paper
- DEISENHOFER, I., KOLB, C., NDREPEPA, G., SCHREIECK, J., KARCH, M., SCHMIEDER, S., ZRENNER, B., & SCHMITT, C. (2001). Do Current Dual Chamber Cardioverter Defibrillators Have Advantages Over Conventional Single Chamber Cardioverter Defibrillators in Reducing Inappropriate Therapies? A Randomized, Prospective Study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2001.00134.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.