The DOI matches its Crossref record.
Prevention of Chronic Atrial Fibrillation by Pacing in the Region of Bachmann's Bundle: Results of a Multicenter Randomized Trial
Open accessAbstract
Bachmann's Bundle Pacing for AF Prevention. Introduction: Atrial pacing locations that decrease atrial activation and recovery time may be preferable in patients with a history of atrial arrhythmias. This multicenter prospective randomized study compared the efficacy of Bachmann's bundle (BB) region pacing to right atrial appendage (RAA) pacing in patients with recurrent paroxysmal atrial fibrillation (AF). Methods and Results: Patients with standard pacing indications (n = 120, 70 ± 11 years) were randomized to atrial pacing in either the RAA (n = 57) or BB region (n = 63). Implantation time was similar between groups (88 ± 36 min[n = 38] for BB vs 83 ± 34 min [n = 34] for RAA). No differences in pacing threshold, impedance, or sensing between BB and RAA groups were observed at implantation or after the 6‐week, 6‐month, and 1‐year follow‐up periods. Average length of follow‐up was 12.6 ± 7.4 months for the BB group and 11.8 ± 8.0 months for the RAA pacing group. The percentage of atrial pacing was similar between groups (61% ± 34% RAA vs 65% ± 31% BB at 2 weeks after implant). BB atrial pacing significantly (P < 0.05) shortened p wave duration compared with sinus rhythm (123 ± 21 msec vs 132 ± 21 msec, n = 50) 2 weeks after implant. In contrast, p wave duration was longer during atrial pacing from the RAA position compared with sinus rhythm (148 ± 23 msec vs 123 ± 23 msec, n = 37). Additionally, p wave duration was shorter during BB pacing than during RAA pacing. Patients with BB pacing had a higher (P < 0.05) rate of survival free from chronic AF (75%) compared with patients with RAA pacing (47%) at 1 year. Conclusion: BB region pacing is safe and effective for attenuating the progression of AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.018 · Cited by 467
Metadata
- Authors
- BAILIN, S. J., ADLER, S., & GIUDICI, M.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 12
- Issue
- 8
- Pages
- 912-917
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1974999935
- Cited by
- 274
- References
- 0
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevention of Chronic Atrial Fibrillation by Pacing in the Region of Bachmann's Bundle: Results of a Multicenter Randomized Trial. https://app.cochat.ai/papers/10.1046/j.1540-8167.2001.00912.x
- The paper
- BAILIN, S. J., ADLER, S., & GIUDICI, M. (2001). Prevention of Chronic Atrial Fibrillation by Pacing in the Region of Bachmann's Bundle: Results of a Multicenter Randomized Trial. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2001.00912.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.