Clinical Experience with a Dual‐Chamber Implantable Cardioverter Defibrillator to Treat Atrial Tachyarrhythmias

GOLD, MICHAEL R., SULKE, NEIL, SCHWARTZMAN, DAVID S., MEHRA, RAHUL, EULER, DAVID E. · 2001 · Journal of Cardiovascular Electrophysiology
Cited by 88

The DOI matches its Crossref record.

Abstract

Dual‐Chamber ICD and Atrial Tachyarrhythmia. Introduction: This study evaluated the safety and efficacy of a new dual‐chamber implantable cardioverter defibrillator (ICD) to detect and treat atrial tachyarrhythmias in patients with drug‐refractory atrial fibrillation (AF) and no indication for a ventricular ICD. Methods and Results: A dual‐chamber ICD (Medtronic 7250 Jewel AF) was implanted in 144 of 146 patients. The device discriminates atrial tachycardia from AF based on cycle length and regularity, and uses atrial overdrive pacing as well as shocks to terminate tachyarrhythmia episodes. Patients were followed for an average of 12.6 ± 6.2 months. Use of antiarrhythmic drugs was 63% at baseline and did not change over time. Kaplan‐Meier estimates of 12‐month complication‐free survival, device therapy survival, and patient survival were 85%, 91%, and 98%, respectively. Positive predictive accuracy of spontaneous atrial tachyarrhythmia detection was 99%, while atrial overdrive pacing and shocks terminated 40% and 87% of treated episodes, respectively. Median duration of successfully treated episodes was 8.9 minutes versus 144 minutes for the therapy failures. There was no reduction in the use of patient‐activated shock therapy over time; at the 12‐month follow‐up evaluation, 94% of patients were in sinus rhythm. Ventricular tachyarrhythmias (67 episodes) were detected and appropriately treated in 7.6% of patients. Conclusion: This dual‐chamber ICD appears to be safe and well tolerated in patients with drug‐refractory symptomatic atrial tachyarrhythmias. The device, used in combination with drugs, effectively treats atrial tachyarrhythmias with pacing and/or shock therapies and decreases the median episode duration. In addition, the device protects from ventricular tachyarrhythmias in patients with AF and structural heart disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2001.01247.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
GOLD, M. R., SULKE, N., SCHWARTZMAN, D. S., MEHRA, R., & EULER, D. E.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2001-11
Volume
12
Issue
11
Pages
1247-1253
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2080465466
Cited by
88
References
0
FWCI
9.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.