Abstract

AF After Pacemaker Implantation. Introduction: Newer implantable pulse generators have data storage capabilities that permit detection of multiple episodes of atrial fibrillation (AF). This study evaluated the clinical predictors and time course of AF development in a general pacemaker population. Methods and Results: Patients (n = 231) received DDDR pacemakers with features that permit detection and storage of information about the date, time of onset, and duration of multiple, sequential episodes of AF. Patients were followed for 718 ± 383 days. Time to first occurrence of AF, interval between first and second episode of AF, and total AF burden were determined at each follow‐up visit. AF occurred more often in patients (68%) with sinus node disease than in patients with AV block (37%; P < 0.001). Time to first occurrence of AF was 21.2 days (95% confidence interval [CI] 14.7 to 30.6 days) after pacemaker implantation. AF burden initially decreased significantly in patients (0.8 hours/day, 95% CI 0.7 to 0.9 at 8 weeks after implant vs 0.6 hours/day, 95% CI 0.4 to 0.8 at 12 months after implant; P = 0.005) but then increased significantly during long‐term follow‐up (2.0 hours/day, 95% CI 1.0 to 3.7 at 48 months after implant; P = 0.008). The long‐term increase in AF burden was seen predominantly in patients with sinus node disease. A prior history of AF and the duration of follow‐up were independent predictors of AF occurrence. Conclusion: AF develops frequently after dual‐chamber pacemaker implantation. AF burden increases progressively over the long term.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2002.00542.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 126

Metadata

Authors
GILLIS, A. M., & MORCK, M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2002-06
Volume
13
Issue
6
Pages
542-547
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2075702946
Cited by
126
References
0
FWCI
3.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atrial Fibrillation After DDDR Pacemaker Implantation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2002.00542.x
The paper
GILLIS, A. M., & MORCK, M. (2002). Atrial Fibrillation After DDDR Pacemaker Implantation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2002.00542.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.