The DOI matches its Crossref record.
Cerebrovascular Complication Associated with Pulmonary Vein Ablation
Abstract
Stroke and PV Ablation. Introduction: Radiofrequency (RF) ablation has become an established treatment modality for patients with paroxysmal atrial fibrillation (AF). A principal limitation of RF catheter ablation is the risk of thromboembolism. Stroke as a complication after ablation of triggers of AF has not been previously reported. Methods and Results: Fifty‐six patients underwent RF ablation for a focal source of AF. Forty‐nine patients (86%) had AF triggers in ≥1 pulmonary vein. Mean procedure time was 227 ± 74 minutes. Cerebrovascular event occurred in 3 (5%) patients, all >60 years old. Two of the three patients had a prior history of transient ischemic attacks. Conclusion: The risk of stroke from RF ablation may be higher in paroxysmal AF patients with prior transient ischemic attack.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationWolf, R. K., Schneeberger, E. W., Osterday, R., Miller, D., Merrill, W., Flege, J. B., & Gillinov, A. M. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.03.041 · Cited by 392
Di Biase, L., Burkhardt, J. D., Mohanty, P., Sanchez, J., Horton, R., Gallinghouse, G. J., Lakkireddy, D., Verma, A., Khaykin, Y., Hongo, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.921320 · Cited by 294
Left atrial catheter ablation and ischemic stroke
Haeusler, K. G., Kirchhof, P., & Endres, M. (2012) · Stroke · doi:10.1161/strokeaha.111.627067 · Cited by 77
Metadata
- Authors
- KOK, L. C., MANGRUM, J. M., HAINES, D. E., & MOUNSEY, J. P.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2002-08
- Volume
- 13
- Issue
- 8
- Pages
- 764-767
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2025686055
- Cited by
- 183
- References
- 0
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebrovascular Complication Associated with Pulmonary Vein Ablation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2002.00764.x
- The paper
- KOK, L. C., MANGRUM, J. M., HAINES, D. E., & MOUNSEY, J. P. (2002). Cerebrovascular Complication Associated with Pulmonary Vein Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2002.00764.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.