The DOI matches its Crossref record.
Anatomy of the Pulmonary Veins in Patients with Atrial Fibrillation and Effects of Segmental Ostial Ablation Analyzed by Computed Tomography
Open accessAbstract
Pulmonary Vein Anatomy. Introduction: The anatomic arrangement of pulmonary veins (PVs) is variable. No prior studies have quantitatively analyzed the effects of segmental ostial ablation on the PVs. The aim of this study was to determine the effect of segmental ostial radiofrequency ablation on PV anatomy in patients with atrial fibrillation (AF). Methods and Results: Three‐dimensional models of the PVs were constructed from computed tomographic (CT) scans in 58 patients with AF undergoing segmental ostial ablation to isolate the PVs and in 10 control subjects without a history of AF. CT scans were repeated approximately 4 months later. PV and left atrial dimensions were measured with digital calipers. Four separate PV ostia were present in 47 subjects; 3 ostia were present in 2 subjects; and 5 ostia were present in 9 subjects. The superior PVs had a larger ostium than the inferior PVs. Patients with AF had a larger left atrial area between the PV ostia and larger ostial diameters than the controls. Segmental ostial ablation resulted in a 1.5 ± 3.2 mm narrowing of the ostial diameter. A 28% to 61% focal stenosis was present 7.6 ± 2.2 mm from the ostium in 3% of 128 isolated PVs. There were no instances of symptomatic PV stenosis during a mean follow‐up of 245 ± 105 days. Conclusion: CT of the PVs allows identification of anatomic variants prior to catheter ablation procedures. Segmental ostial ablation results in a significant but small reduction in ostial diameter. Focal stenosis occurs infrequently and is attributable to delivery of radiofrequency energy within the PV. (J Cardiovasc Electrophysiol, Vol. 14, pp. 150‐155, February 2003)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citation
Metadata
- Authors
- SCHARF, C., SNEIDER, M., CASE, I., CHUGH, A., LAI, S. W. K., PELOSI, F., KNIGHT, B. P., KAZEROONI, E., MORADY, F., & ORAL, H.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2003-02
- Volume
- 14
- Issue
- 2
- Pages
- 150-155
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1797740021
- Cited by
- 227
- References
- 0
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anatomy of the Pulmonary Veins in Patients with Atrial Fibrillation and Effects of Segmental Ostial Ablation Analyzed by Computed Tomography. https://app.cochat.ai/papers/10.1046/j.1540-8167.2003.02444.x
- The paper
- SCHARF, C., SNEIDER, M., CASE, I., CHUGH, A., LAI, S. W. K., PELOSI, F., KNIGHT, B. P., KAZEROONI, E., MORADY, F., & ORAL, H. (2003). Anatomy of the Pulmonary Veins in Patients with Atrial Fibrillation and Effects of Segmental Ostial Ablation Analyzed by Computed Tomography. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2003.02444.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.