Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Implications of Implantable Cardioverter Defibrillator Therapy in Congenital Heart Disease and Pediatrics

ALEXANDER, MARK E., CECCHIN, FRANK, WALSH, EDWARD P., TRIEDMAN, JOHN K., BEVILACQUA, LAURA M., BERUL, CHARLES I.·2004·Journal of Cardiovascular Electrophysiology

Abstract

Introduction: The incidence of appropriate and inappropriate discharges, indicators of system failure, and clinical implications of implantable cardioverter defibrillator (ICD) therapy in children and young adults with heart disease is poorly defined. Methods and Results: In a retrospective study at a single medical center, a total of 90 ICD procedures were performed in 76 patients younger than age 30 years (median 16 years, range 1–30): 42% with congenital heart disease, 33% with primary electrical disease, 17% with hypertrophic cardiomyopathy, and 8% with idiopathic dilated cardiomyopathy. Indications for ICD included arrest or sustained ventricular tachycardia (n = 27), and combinations of syncope (n = 32), palpitations (n = 17), spontaneous ventricular arrhythmia (n = 40), inducible ventricular tachycardia (n = 36), or severe hypertrophic cardiomyopathy. Transvenous dual‐chamber ICDs were implanted in 29 patients. Subcutaneous arrays or epicardial patches were used in 9 patients. Over a median 2‐year follow‐up, 28% of patients received appropriate shocks for ventricular tachycardia (median 13 months to first shock) and 25% experienced inappropriate shocks for multiple causes (median 16 months). With multivariate analysis, growth strongly correlated with lead failure (odds ratio 73, 3.5–1530, P = 0.006). Complications occurred in 29 patients, including lead failure in 16 (21%), ICD “storm” with sequential shocks in 5, and infection in 2 patients. No deaths were attributable to ICD placement or subsequent device failure. Conclusion: ICD therapy can effectively manage malignant arrhythmias in selected pediatric and congenital heart patients. Spurious shocks or ICD storm may increase morbidity and emphasize the need for concomitant medical and ablative therapy. ICD lead failure was relatively frequent in this population. (J Cardiovasc Electrophysiol, Vol. 15, pp. 72‐76, January 2004)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.03388.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 281

Metadata

Authors
ALEXANDER, M. E., CECCHIN, F., WALSH, E. P., TRIEDMAN, J. K., BEVILACQUA, L. M., & BERUL, C. I.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-01
Volume
15
Issue
1
Pages
72-76
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2103983101
Cited by
281
References
1
FWCI
9.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implications of Implantable Cardioverter Defibrillator Therapy in Congenital Heart Disease and Pediatrics. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.03388.x
The paper
ALEXANDER, M. E., CECCHIN, F., WALSH, E. P., TRIEDMAN, J. K., BEVILACQUA, L. M., & BERUL, C. I. (2004). Implications of Implantable Cardioverter Defibrillator Therapy in Congenital Heart Disease and Pediatrics. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.03388.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.