CoChat

Efficacy and Safety of Segmental Ostial Versus Circumferential Extra‐Ostial Pulmonary Vein Isolation for Atrial Fibrillation

Open access
MANSOUR, MOUSSA, RUSKIN, JEREMY, KEANE, DAVID · 2004 · Journal of Cardiovascular Electrophysiology
Cited by 168

The DOI matches its Crossref record.

Abstract

Introduction: Pulmonary vein (PV) isolation for atrial fibrillation (AF) can be performed using a segmental ostial or a circumferential extra‐ostial approach. The relative merits and potential limitations of each approach are currently debated. Here we report our early experience with each of these approaches, including their relative efficacy and safety. Methods and Results: Forty patients with drug‐refractory AF underwent segmental ostial PV isolation and were compared to 40 consecutive patients who underwent PV isolation using a circumferential extra‐ostial approach. The latter approach described here is novel in two aspects: (1) the endpoint for ablation was PV isolation and not only delay in left atrial to PV conduction time, and (2) isolation of the right and left PVs was achieved by a single encirclement of ipsilateral veins. At follow‐up, 60% of the patients in the segmental group were free of AF compared to 75% of the patients in the circumferential group. There was one thromboembolic cerebrovascular complication during the ablation procedure in each group. Conclusion: PV isolation using a circumferential extra‐ostial approach, where the ipsilateral PVs are isolated together by one encircling line of block using electroanatomic mapping, is a technically feasible procedure. This approach is at least as effective and safe as the more established segmental ostial approach for AF ablation. (J Cardiovasc Electrophysiol, Vol. 15, pp. 532‐537, May 2004)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.03503.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
MANSOUR, M., RUSKIN, J., & KEANE, D.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-04-30
Volume
15
Issue
5
Pages
532-537
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2007911431
Cited by
168
References
0
FWCI
11.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy and Safety of Segmental Ostial Versus Circumferential Extra‐Ostial Pulmonary Vein Isolation for Atrial Fibrillation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.03503.x
The paper
MANSOUR, M., RUSKIN, J., & KEANE, D. (2004). Efficacy and Safety of Segmental Ostial Versus Circumferential Extra‐Ostial Pulmonary Vein Isolation for Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.03503.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.