Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record.

Assessment of Pulmonary Vein Anatomic Variability by Magnetic Resonance Imaging: Implications for Catheter Ablation Techniques for Atrial Fibrillation

Open access
MANSOUR, MOUSSA, HOLMVANG, GODTFRED, SOSNOVIK, DAVID, MIGRINO, RAYMOND, ABBARA, SUHNY, RUSKIN, JEREMY, KEANE, DAVID · 2004 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Pulmonary vein (PV) isolation for atrial fibrillation (AF) currently is performed using either an ostial or an extra‐ostial approach. The objective of this study was to analyze by three‐dimensional (3D) magnetic resonance angiography (MRA) the anatomy of the PVs in order to detect structural variability that would impact the choice of ablation approach. Methods and Results: Three‐dimensional MRA was performed in 105 patients undergoing PV isolation. The ostial diameter, branching pattern, and PV angulation were analyzed. Fifty‐nine (56%) patients had the typical pattern of 4 PVs with 4 separate ostia, 30 (29%) patients had an additional PV, and 18 (17%) patients had a left common PV trunk. In two patients, there were three right‐sided veins and a common left‐sided trunk, giving rise to four ostia: three on the right and one on the left. Two different populations of right middle PVs were noted: one where the additional vein projected anteriorly to drain the right middle lobe and one posterior to drain the superior portion of the right lower lobe. The average intrapatient variability in PV diameter was 7.9 ± 4.2 mm. The PV ostium was <10 mm in 26 (25%) patients and >25 mm in 15 (14%) patients. The first branch originated 6.7 ± 2.3 mm from the ostium. The left superior, right superior, right inferior, and left inferior PVs were found to enter the left atrium at the following angles: 32 ± 13°, 131 ± 11°, 206 ± 16°, and 329 ± 14°, respectively. Forty‐nine patients (47%) had at least one funnel shaped PV. Conclusion: This largest PV imaging study to date demonstrates that MRA is a valuable tool that allows detection of marked intrapatient and interpatient anatomic variability of the PVs. These findings suggest that, at least in some patients, circumferential extra‐ostial left atrial encirclement of the PVs may be preferable to ostial PV isolation. These findings also may have significant implications on the future development of coil‐ and balloon‐based catheter ablation designs for AF ablation. (J Cardiovasc Electrophysiol, Vol. 15, pp. 387‐393, April 2004)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.03515.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 207

Metadata

Authors
MANSOUR, M., HOLMVANG, G., SOSNOVIK, D., MIGRINO, R., ABBARA, S., RUSKIN, J., & KEANE, D.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-04
Volume
15
Issue
4
Pages
387-393
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2052339069
Cited by
207
References
0
FWCI
9.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Pulmonary Vein Anatomic Variability by Magnetic Resonance Imaging: Implications for Catheter Ablation Techniques for Atrial Fibrillation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.03515.x
The paper
MANSOUR, M., HOLMVANG, G., SOSNOVIK, D., MIGRINO, R., ABBARA, S., RUSKIN, J., & KEANE, D. (2004). Assessment of Pulmonary Vein Anatomic Variability by Magnetic Resonance Imaging: Implications for Catheter Ablation Techniques for Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.03515.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.