CoChat

Predictors of Recurrence Following Catheter Ablation of Atrial Fibrillation Using an Irrigated‐Tip Ablation Catheter

VASAMREDDY, CHANDRASEKHAR R., LICKFETT, LARS, JAYAM, VINOD K., NASIR, KHURRAM, BRADLEY, DAVID J., ELDADAH, ZAYD, DICKFELD, TIMM, BERGER, RONALD, CALKINS, HUGH · 2004 · Journal of Cardiovascular Electrophysiology
Cited by 141

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Introduction: The aims of this study were to identify predictors of recurrence after catheter ablation of atrial fibrillation (AF) and to report the safety and efficacy of catheter ablation of AF using an irrigated‐tip ablation catheter. Methods and Results: Seventy‐five consecutive patients (51 men [68%]; age 54 ± 13 years) with symptomatic drug‐refractory paroxysmal (42 patients), persistent (21 patients), or permanent (12 patients) AF underwent catheter ablation of AF using an irrigated‐tip ablation catheter and a standard ablation strategy, which involved electrical isolation of all pulmonary veins (PVs) and creation of a cavotricuspid linear lesion. At 10.5 ± 7.5 months of follow‐up following a single (n = 75) or redo ablation procedure (n = 11), 39 (52%) of the 75 patients were free of AF, 10 were improved (13%), and 26 had experienced no benefit from the ablation procedure (35%). Seventy‐six percent of patients with paroxysmal AF were free from recurrent AF. The most significant complications were two episodes of pericardial tamponade, mitral valve injury in one patient, two strokes, and complete but asymptomatic PV stenosis in one patient. Cox proportional hazards multivariate regression analysis identified the presence of persistent AF, permanent AF, and age >50 years prior to the ablation are the only independent predictors of AF recurrence after the first PV isolation procedure. Conclusion: Catheter ablation of AF using a strategy involving isolation of all PVs and creation of a linear lesion in the cavotricuspid isthmus using cooled radiofrequency energy is associated with moderate efficacy and an important risk for complications. The best results of this procedure are achieved in the subset of patients who are younger than 50 years and have only paroxysmal AF. (J Cardiovasc Electrophysiol, Vol. 15, pp. 692‐697, June 2004)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.03538.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 141

Metadata

Authors
VASAMREDDY, C. R., LICKFETT, L., JAYAM, V. K., NASIR, K., BRADLEY, D. J., ELDADAH, Z., DICKFELD, T., BERGER, R., & CALKINS, H.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-05-28
Volume
15
Issue
6
Pages
692-697
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2137789976
Cited by
141
References
1
FWCI
7.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.