CoChat

Prevalence of Asymptomatic Recurrences of Atrial Fibrillation After Successful Radiofrequency Catheter Ablation

Open access
ORAL, HAKAN, VEERAREDDY, SRIKAR, GOOD, ERIC, HALL, BURR, CHEUNG, PETER, TAMIRISA, KAMALA, HAN, JIHN, FORTINO, JACKIE, CHUGH, AMAN, BOGUN, FRANK, PELOSI, FRANK, MORADY, FRED · 2004 · Journal of Cardiovascular Electrophysiology
Cited by 119

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Introduction: The long‐term efficacy of radiofrequency catheter ablation of atrial fibrillation (AF) has been based on patient‐reported symptoms suggestive of AF. However, asymptomatic recurrences of AF may remain undetected. The aim of this study was to determine the prevalence of asymptomatic recurrences of AF after an apparently successful catheter ablation procedure for AF. Methods and Results: Among 244 consecutive patients (mean age 53 ± 11 years) who underwent a pulmonary vein isolation procedure for symptomatic paroxysmal AF and who reported no symptoms of recurrent AF at ≥6 months after the procedure, 60 patients with a history of ≥1 episode of AF per week were asked to participate in this study. Preablation, these patients had experienced 19 ± 13 episodes of AF per month. The patients were provided with a patient‐activated transtelephonic event recorder for 30 days, a mean of 642 ± 195 days after the ablation procedure, and were asked to record and transmit recordings on a daily basis and whenever they felt palpitations. Seven patients (12%) felt palpitations during the study, although they had not experienced symptoms previously. Each of these 7 patients had an episode of AF documented with the event monitor during symptoms. In these 7 patients, the mean number of episodes per month decreased from 19 ± 14 preablation to 3 ± 1 postablation (P < 0.001). Among the 53 asymptomatic patients, an episode of AF was captured in 1 (2%) patient during the study period. Conclusion: Asymptomatic recurrences of AF after an apparently successful catheter ablation procedure for symptomatic paroxysmal AF are infrequent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.04055.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 119

Metadata

Authors
ORAL, H., VEERAREDDY, S., GOOD, E., HALL, B., CHEUNG, P., TAMIRISA, K., HAN, J., FORTINO, J., CHUGH, A., BOGUN, F., PELOSI, F., & MORADY, F.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-08
Volume
15
Issue
8
Pages
920-924
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2152346596
Cited by
119
References
1
FWCI
10.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prevalence of Asymptomatic Recurrences of Atrial Fibrillation After Successful Radiofrequency Catheter Ablation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.04055.x
The paper
ORAL, H., VEERAREDDY, S., GOOD, E., HALL, B., CHEUNG, P., TAMIRISA, K., HAN, J., FORTINO, J., CHUGH, A., BOGUN, F., PELOSI, F., & MORADY, F. (2004). Prevalence of Asymptomatic Recurrences of Atrial Fibrillation After Successful Radiofrequency Catheter Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.04055.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.