The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Pulmonary Vein Antrum Isolation: Intracardiac Echocardiography‐Guided Technique
Abstract
Several techniques are used for AF ablation, but no general consensus exists as to which technique is the most effective. At our center, we have developed a technique for isolating the pulmonary veins (PVs) at their antrum. The technique is guided by intracardiac echocardiography (ICE) and mapping with a circular (Lasso) catheter. Our technique was developed based on four crucial principles: 1. Precisely identifying the true border of the PV antrum. 2. Electrically isolating all of the PVs at the level of the antrum. 3. Avoiding risk of PV stenosis by ablating outside of the antrum. 4. Minimizing risk of other complications, such as perforation and stroke, by direct visualization during transseptal access and radiofrequency (RF) ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marrouche, N. F., Martin, D. O., Wazni, O., Gillinov, A. M., Klein, A., Bhargava, M., Saad, E., Bash, D., Yamada, H., Jaber, W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000070541.83326.15 · Cited by 512
Self-citationChen, M. S., Marrouche, N. F., Khaykin, Y., Gillinov, A. M., Wazni, O., Martin, D. O., Rossillo, A., Verma, A., Cummings, J., Erciyes, D., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.056 · Cited by 370
Self-citationBhargava, M., MARROUCHE, N. F., Martin, D. O., Schweikert, R. A., Saliba, W. I., Saad, E., Bash, D., Williams‐Andrews, M., Rossillo, A., Erciyes, D., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03266.x · Cited by 113
Self-citationPerez‐Lugones, A., Schvartzman, P. R., Schweikert, R. A., TCHOU, P. J., Saliba, W. I., MARROUCHE, N. F., CASTLE, L. W., White, R. D., & Natale, A. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00144.x · Cited by 49
Self-citation
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.009 · Cited by 1,158
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121
Oakes, R. S., Badger, T. J., Kholmovski, E. G., Akoum, N., Burgon, N. S., Fish, E. N., Blauer, J. J. E., Rao, S. N., DiBella, E. V. R., Segerson, N. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.811877 · Cited by 1,123
Self-citationFuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Metadata
- Authors
- VERMA, A., MARROUCHE, N. F., & NATALE, A.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2004-10-28
- Volume
- 15
- Issue
- 11
- Pages
- 1335-1340
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1951667504
- Cited by
- 315
- References
- 4
- FWCI
- 22.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.