The DOI matches its Crossref record.
Increased Intensity of Anticoagulation May Reduce Risk of Thrombus During Atrial Fibrillation Ablation Procedures in Patients with Spontaneous Echo Contrast
Abstract
Introducton:A 10% incidence of left atrial (LA) thrombus formation has been detected using intracardiac echocardiography (ICE) imaging monitoring during LA ablation for atrial fibrillation (AF). The aim of this study was to determine if the intensity of anticoagulation reduces LA thrombus formation during pulmonary vein isolation procedure in patients with AF and spontaneous echo contrast (SEC). Methods and Results:We studied 511 patients (age 56 ± 10 years) undergoing pulmonary vein ostial isolation/ablation using radiofrequency energy. SEC was detected in 179 of 511 patients with ICE imaging before dual transseptal catheterization. All patients were anticoagulated with heparin to achieve activated clotting time (ACT) 250–300 seconds (group I) or >300 seconds (group II) confirmed at 30‐minute intervals. SEC was detected in 49/294 (16.7%) patients in group I versus 130/217 (59.9%) in group II (P < 0.0001). LA thrombus was observed in 33/294 (11.2%) patients in group I versus 6/217 (2.8%) in group II (P < 0.05). For those patients with SEC, LA thrombus was observed in 22/49 (44.9%) in group I versus 2/61 (4.6%) in group II (P < 0.0001). There were no significant differences in age, number of unsuccessful drugs, persistent AF, left ventricular ejection fraction, and LA diameter between the two groups. No clinical embolic event was observed with withdrawal of LA thrombus to the RA. Conclusion:ICE‐diagnosed SEC before transseptal catheterization identifies an increased risk of LA thrombus. Increased intensity of heparin anticoagulation (ACT >300 seconds) during LA ablation for AF may prevent LA thrombus formation especially in patients with SEC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citation
Metadata
- Authors
- REN, J., MARCHLINSKI, F. E., CALLANS, D. J., GERSTENFELD, E. P., DIXIT, S., LIN, D., NAYAK, H. M., & HSIA, H. H.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-04-12
- Volume
- 16
- Issue
- 5
- Pages
- 474-477
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2103329068
- Cited by
- 221
- References
- 0
- FWCI
- 10.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increased Intensity of Anticoagulation May Reduce Risk of Thrombus During Atrial Fibrillation Ablation Procedures in Patients with Spontaneous Echo Contrast. https://app.cochat.ai/papers/10.1046/j.1540-8167.2005.40465.x
- The paper
- REN, J., MARCHLINSKI, F. E., CALLANS, D. J., GERSTENFELD, E. P., DIXIT, S., LIN, D., NAYAK, H. M., & HSIA, H. H. (2005). Increased Intensity of Anticoagulation May Reduce Risk of Thrombus During Atrial Fibrillation Ablation Procedures in Patients with Spontaneous Echo Contrast. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2005.40465.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.