How Close Are the Phrenic Nerves to Cardiac Structures? Implications for Cardiac Interventionalists
Abstract
Background: Phrenic nerve injury is a recognized complication following cardiac intervention or surgery. With increasing use of transcatheter procedures to treat drug‐refractory arrhythmias, clarification of the spatial relationships between the phrenic nerves and important cardiac structures is essential to reduce risks. Methods and Results: We examined by gross dissection the courses of the right and left phrenic nerves in 19 cadavers. Measurements were made of the minimal and maximal distances of the nerves to the superior caval vein, superior cavoatrial junction, right pulmonary veins, and coronary veins. Histologic studies were carried out on tissues from six cavaders. Tracing the course of the right phrenic nerve revealed its close proximity to the superior caval vein (minimum 0.3 ± 0.5 mm) and the right superior pulmonary vein (minimum 2.1 ± 0.4 mm). The anterior wall of the right superior pulmonary vein was <2 mm from the right phrenic nerve in 32% of specimens. The left phrenic nerve passed over the obtuse cardiac margin and the left obtuse marginal vein and artery in 79% of specimens. In the remaining specimens, its course was anterosuperior, passing over the main stem of the left coronary artery or the anterior descending artery and great cardiac vein. Conclusions: The right phrenic nerve is at risk when ablations are carried out in the superior caval vein and the right superior pulmonary vein. The left phrenic nerve is vulnerable during lead implantation into the great cardiac and left obtuse marginal veins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Metadata
- Authors
- SÁNCHEZ‐QUINTANA, D., CABRERA, J. A., CLIMENT, V., FARRÉ, J., WEIGLEIN, A., & HO, S. Y.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-02-24
- Volume
- 16
- Issue
- 3
- Pages
- 309-313
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2004335953
- Cited by
- 251
- References
- 0
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How Close Are the Phrenic Nerves to Cardiac Structures? Implications for Cardiac Interventionalists. https://app.cochat.ai/papers/10.1046/j.1540-8167.2005.40759.x
- The paper
- SÁNCHEZ‐QUINTANA, D., CABRERA, J. A., CLIMENT, V., FARRÉ, J., WEIGLEIN, A., & HO, S. Y. (2005). How Close Are the Phrenic Nerves to Cardiac Structures? Implications for Cardiac Interventionalists. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2005.40759.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.