Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 346

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Clinical Implications of Cumulative Right Ventricular Pacing in the Multicenter Automatic Defibrillator Trial II

STEINBERG, JONATHAN S., FISCHER, AVI, WANG, PAUL, SCHUGER, CLAUDIO, DAUBERT, JAMES, MCNITT, SCOTT, ANDREWS, MARK, BROWN, MARY, HALL, W. JACKSON, ZAREBA, WOJCIECH, MOSS, ARTHUR J., MADIT II Investigators·2005·Journal of Cardiovascular Electrophysiology

Abstract

Introduction:This study was designed to assess whether right ventricular pacing in the implantable cardioverter defibrillator (ICD) arm of the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II was associated with an unfavorable outcome. Methods and Results:Data on the number of ventricular paced beats were available in 567 (76%) of 742 MADIT II patients with ICDs. The number of ventricular paced beats over the total number of beats showed a bimodal distribution with patients being predominantly paced or nonpaced. Therefore, patients were dichotomized at 0–50% and 51–100% of cumulative pacing with median pacing rate 0.2% and 95.6%, respectively. Endpoints included new or worsening heart failure, appropriate ICD therapy for VT/VF, and the combined endpoint of heart failure or death. Clinical features associated with frequent ventricular pacing included age ≥65 years, advanced NYHA heart failure class, LVEF < 0.25, first degree AV and bundle branch block, and amiodarone use. During follow‐up, 119 patients (21%) had new or worsened heart failure, 130 (23%) had new or worsened heart failure or death, and 142 (25%) had appropriate therapy for VT/VF. In comparison to patients with infrequent pacing, those with frequent pacing had significantly higher risk of new or worsened heart failure (hazard ratio = 1.93; P = 0.002) and VT/VF requiring ICD therapy (HR = 1.50; P = 0.02). Conclusions:Patients in MADIT II who were predominantly paced had a higher rate of new or worsened heart failure and were more likely to receive therapy for VT/VF. These results suggest the deleterious consequences of RV pacing, particularly in the setting of severe LV dysfunction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2005.50038.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 346

Metadata

Authors
STEINBERG, J. S., FISCHER, A., WANG, P., SCHUGER, C., DAUBERT, J., MCNITT, S., ANDREWS, M., BROWN, M., HALL, W. J., ZAREBA, W., MOSS, A. J., & MADIT II Investigators
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2005-04
Volume
16
Issue
4
Pages
359-365
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2050949463
Cited by
346
References
2
FWCI
17.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Clinical Implications of Cumulative Right Ventricular Pacing in the Multicenter Automatic Defibrillator Trial II. https://app.cochat.ai/papers/10.1046/j.1540-8167.2005.50038.x
The paper
STEINBERG, J. S., FISCHER, A., WANG, P., SCHUGER, C., DAUBERT, J., MCNITT, S., ANDREWS, M., BROWN, M., HALL, W. J., ZAREBA, W., MOSS, A. J., & MADIT II Investigators. (2005). The Clinical Implications of Cumulative Right Ventricular Pacing in the Multicenter Automatic Defibrillator Trial II. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2005.50038.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.