CoChat

Heart Rate Variability in Obstructive Sleep Apnea: A Prospective Study and Frequency Domain Analysis

Open access
Gula, Lorne J, Krahn, Andrew D, Skanes, Allan, Ferguson, Kathleen A, George, Charles, Yee, Raymond, Klein, George J · 2003 · Annals of Noninvasive Electrocardiology
Cited by 131

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Cyclic variation of the heart rate is observed during apneic spells in obstructive sleep apnea (OSA). We hypothesized that autonomic changes would affect frequency‐domain measures of heart rate variability (HRV). Methods: We studied 20 patients (15 men, 5 women, mean age 47.2 ± 12.2 years) with suspected OSA undergoing overnight polysomnography, and five patients (4 men, 1 woman, mean age 49.2 ± 8.6 years) with recently diagnosed sleep apnea undergoing polysomnography while wearing continuous positive airway pressure (CPAP). Holter monitors were applied during sleep studies and data were analyzed in 5‐minute blocks over the course of the night. Using spectral analysis, low frequency (LF) and high frequency (HF) powers were calculated for each interval. Overall mean and standard deviation (SD) for LF power, HF power, and the LF:HF ratio were recorded for each patient. Comparisons were made between patients with severe OSA (apnea hypopnea index (AHI) > 30, n = 8), moderate OSA (AHI 1–30, n = 5), without OSA (AHI < 10, n = 7), and patients wearing CPAP (n = 5). Results: Assessment of overnight LF or HF power revealed no significant difference between the four groups. The LF:HF ratio, which represents sympathovagal balance, was higher among those with moderate disease compared to normals and those with severe OSA (both P = 0.037). The standard deviation of the LF:HF ratio was higher among those with moderate disease compared to normals (P = 0.0064) and those with severe OSA (P = 0.0006). OSA patients receiving CPAP behaved like patients with moderate OSA, with increased SD of the LF:HF ratio. Conclusions: The observed changes in the LF:HF ratio and its SD suggest an increased sympathetic tone and discordance in sympathovagal activity in moderate OSA, which is blunted in severe OSA. CPAP may restore autonomic defects, characteristic of severe OSA, to moderate levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1542-474x.2003.08209.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 131

Metadata

Authors
Gula, L. J., Krahn, A. D., Skanes, A., Ferguson, K. A., George, C., Yee, R., & Klein, G. J.
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
2003-04
Volume
8
Issue
2
Pages
144-149
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W1987295883
Cited by
131
References
1
FWCI
0.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Rate Variability in Obstructive Sleep Apnea: A Prospective Study and Frequency Domain Analysis. https://app.cochat.ai/papers/10.1046/j.1542-474x.2003.08209.x
The paper
Gula, L. J., Krahn, A. D., Skanes, A., Ferguson, K. A., George, C., Yee, R., & Klein, G. J. (2003). Heart Rate Variability in Obstructive Sleep Apnea: A Prospective Study and Frequency Domain Analysis. Annals of Noninvasive Electrocardiology. https://doi.org/10.1046/j.1542-474x.2003.08209.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.