Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record.

Optical trapping and rotational manipulation of microscopic particles and biological cells using higher-order mode Nd:YAG laser beams

Sato, S., Ishigure, M., Inaba, H.·1991·Electronics Letters

Abstract

A single-beam optical trapping of microscopic particles and biological cells is demonstrated by using higher-order mode Nd : YAG laser beams at 1.064 μm for the first known time. A stronger trapping force by a TEM01* beam than that by a TEM00 beam was observed and 360° rotation of a trapped red blood cell with a TEM0n beam was achieved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/el:19911138

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Sato, S., Ishigure, M., & Inaba, H.
Venue
Electronics Letters
Published
1991-09-26
Volume
27
Issue
20
Pages
1831-1832
ISSN
  • 0013-5194 (ISSN-L)
  • 1350-911X
OpenAlex
W1967173080
Cited by
168
References
0
FWCI
1.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical trapping and rotational manipulation of microscopic particles and biological cells using higher-order mode Nd:YAG laser beams. https://app.cochat.ai/papers/10.1049/el:19911138
The paper
Sato, S., Ishigure, M., & Inaba, H. (1991). Optical trapping and rotational manipulation of microscopic particles and biological cells using higher-order mode Nd:YAG laser beams. Electronics Letters. https://doi.org/10.1049/el%3A19911138

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.