Alternate half-field stimulation technique for SSVEP-based brain–computer interfaces
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A technique of half-field alternate visual stimulation, combined with differential EEG signal measurement, is applied to acquire steady-state brain-evoked signals. Taking the difference of two signals, measured with properly placed electrodes, enhances the visual-evoked potential (VEP) and suppresses the noise components. An array of different-flash-frequency light-emitting-diode (LED) pairs forms a multiple-choice table. By fixating at different LED pairs, the user communicates (by the VEP of corresponding frequency) his/her decision about the selection of the table entry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493
Cited by
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
A Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
“In the half-field alternate visual stimulation designed by Materka et al. [ 24 ], a stimulus in the form of left/right light sources flashing with the same frequency but alternately in time (i.e., with a phase difference of 180 )r esults in an enhanced SNR of the SSVEP on the bipolar lead at O1 and O2. In the frequenc…”
BackgroundEye-blink detection system for human–computer interaction
Królak, A., & Strumiłło, P. (2012) · Universal Access in the Information Society · doi:10.1007/s10209-011-0256-6 · Cited by 237
“Such interfaces enable to operate virtual keyboards [2], manage environmental control systems, use text editors, web browsers or make physical movements [3].”
BackgroundVisual stimulus design for high-rate SSVEP BCI
Wang, Y., Wang, Y.-T., & Jung, T.-P. (2010) · Electronics Letters · doi:10.1049/el.2010.0923 · Cited by 183
Metadata
- Authors
- Materka, A., & Byczuk, M.
- Venue
- Electronics Letters
- Published
- 2006-03-16
- Volume
- 42
- Issue
- 6
- Pages
- 321-322
- ISSN
- 0013-5194 (ISSN-L)
- 1350-911X
- OpenAlex
- W2087810162
- Cited by
- 39
- References
- 1
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.